Results 41 to 50 of about 12,318 (173)
Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and ...
Zwierzchowski Grzegorz +2 more
doaj +1 more source
Given the sensitivity of proton therapy to anatomical variations, this cancer treatment modality is expected to benefit greatly from integration with magnetic resonance (MR) imaging.
Bussmann, Michael +5 more
core +1 more source
Objective: To compare two different treatment planning systems (TPSs) for plan quality and to check the feasibility of VMAT TBI on the Elekta linear accelerator ‘Versa HD’.
Reena Kumari +2 more
doaj +1 more source
Experimental verification of acuros XB in the presence of lung-equivalent heterogeneities [PDF]
Acuros XB (AXB) is a deterministic algorithm that directly accounts for the effects of heterogeneities and improves the accuracy of photon dose calculations in radiotherapy. Nevertheless, the accuracy of AXB inside lung has not been yet fully examined by
Agramunt Chaler, Sebastià +4 more
core +2 more sources
Dosimetric verification of the Elekta motorized wedge
Elekta linear accelerator is equipped with a motorized wedge which produces the wedge angles of less than 60° continuously by the combination of a wedged field and an open field with appropriate proportions. The effective wedge angles for various field sizes and depths were calculated using an analytical formula and a 2-D array detector data.
Behjati, Mahdie +4 more
openaire +1 more source
Dosimetric verification of micro‐MLC based intensity modulated radiation therapy [PDF]
A methodology for the dosimetric verification of micro‐multileaf collimator (mMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The method is similar to that of conventional IMRT patient‐specific quality assurance (QA) with some notable exceptions, particularly, mechanical tests that ...
Basran, Parminder, Yeboah, Collins
openaire +2 more sources
Dosimetric verification of gated delivery of electron beams using a 2D ion chamber array
The purpose of this study was to compare the dosimetric characteristics; such as beam output, symmetry and flatness between gated and non-gated electron beams.
S A Yoganathan +3 more
doaj +1 more source
Intrafractional stability of MR-guided online adaptive SBRT for prostate cancer
Background MR-guided online adaptive stereotactic body radiation therapy (SBRT) for prostate cancer aims to reduce toxicity by full compensation of interfractional uncertainties.
J. Schaule +9 more
doaj +1 more source
A nomogram to determine required seed air kerma strength in planar 131 Cesium permanent seed implant brachytherapy [PDF]
Purpose: Intraoperatively implanted Cesium-131 ( 131 Cs) permanent seed brachytherapy is used to deliver highly localized re-irradiation in recurrent head and neck cancers.
Bar-Ad, Voichita +4 more
core +1 more source
Treating cutaneous T-cell lymphoma with highly irregular surfaces with photon irradiation using rice as tissue compensator. [PDF]
PurposeCutaneous T-cell lymphoma (CTCL) is known to have an excellent response to radiotherapy, an important treatment modality for this disease.
Chakravarti, Arnab +9 more