Dosimetric, mechanical, and geometric verification of conformal dynamic arc treatment [PDF]
A conformal dynamic arc (CD‐arc) technique has been implemented at the S. Giovanni Calibita‐Fatebenefratelli Hospital Radiotherapy Center. This technique is performed by rotational beams and a dynamic multileaf collimator (DMLC): during the treatment delivery the gantry rotates and the field shape, formed by the DMLC changes continuously.
Malatesta, T. +11 more
openaire +2 more sources
Background: Pre-treatment dosimetric verification for patient specific quality assurance has become an essential part of intensity modulated radiation therapy (IMRT).
Sorathan Chanjorakhae +2 more
doaj
Time-resolved dosimetric verification of respiratory-gated radiotherapy exposures using a high-resolution 2D ionisation chamber array [PDF]
The aim of this work was to track and verify the delivery of respiratory-gated irradiations, performed with three versions of TrueBeam linac, using a novel phantom arrangement that combined the OCTAVIUS(®) SRS 1000 array with a moving platform.
Agnew, C.E. +5 more
core +1 more source
This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique.
Sivakumar S +6 more
doaj
Patient-specific independent 3D GammaPlan quality assurance for Gamma Knife Perfexion radiosurgery [PDF]
One of the most important aspects of quality assurance (QA) in radiation therapy is redundancy of patient treatment dose calculation. This work is focused on the patient-specific time and 3D dose treatment plan verification for stereotactic radiosurgery ...
Best +12 more
core +2 more sources
Dosimetric verification by using the ArcCHECK system and 3DVH software for various target sizes. [PDF]
To investigate the usefulness of the 3DVH software with an ArcCHECK 3D diode array detector in newly designed plans with various target sizes.The isocenter dose was measured with an ion-chamber and was compared with the planned and 3DVH predicted doses ...
Jin Ho Song +3 more
doaj +1 more source
Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams [PDF]
Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector
A. Mairani +46 more
core +2 more sources
Dosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcsDosimetric validation for an automatic brain metastases planning software using single-isocenter dynamic conformal arcs. [PDF]
An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic
Andrews, David W. +8 more
core +1 more source
Monitoring Frequency of Intra‐Fraction Patient Motion Using the ExacTrac System for LINAC‐based SRS Treatments [PDF]
Purpose: The aim of this study was to investigate the intra‐fractional patient motion using the ExacTrac system in LINAC‐based stereotactic radiosurgery (SRS).
Kim, Siyong +3 more
core +2 more sources
Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy [PDF]
published_or_final_versio
CHAN, KH +6 more
core +1 more source