Comparison of liver stereotactic body radiotherapy plans based on free breathing and averaged CTs after trans-arterial chemoembolization using lipiodol. [PDF]
Abstract Purpose To identify which CT set is more suitable for predicting the four‐dimensional (4D) cumulative dose distribution in liver stereotactic body radiotherapy (SBRT) with lipiodol retention. Methods For 15 patients, who underwent liver SBRT after trans‐arterial chemoembolization (TACE), volumetric modulated arc therapy (VMAT) plans were ...
Kang SK +6 more
europepmc +2 more sources
Development of a LINAC head model for the CyberKnife VSI-System using EGSnrc Monte Carlo system. [PDF]
Abstract Introduction In order to understand the interaction processes of photons and electrons of the CyberKnife VSI‐System, a modeling of the LINAC head must take place. Here, a Monte Carlo simulation can help. By comparing the measured data with the simulation data, the agreement can be checked. Materials and methods For the Monte Carlo simulations,
Thiele M, Galonske K, Ernst I, Mack A.
europepmc +2 more sources
High spatial resolution dosimetry for radiation oncology with "MagicPlates," a new 976-pixel monolithic silicon detector. [PDF]
Abstract Purpose We introduce the next generation of “MagicPlate” 2D monolithic pixelated semiconductor detectors – MagicPlate‐976 (MP976). It features a larger array area, higher spatial resolution, and does not require external triggering. We perform a comprehensive characterization for small‐field steep‐dose‐gradient dosimetry applications in ...
Filipev I +13 more
europepmc +2 more sources
The aim of this study is to investigate the effects of these Variance reduction techniques on photon fluence and dose calculation efficiency. Different VRTs available in the BEAMnrc code were used to investigate the simulation efficiency for a 6 MV ...
Turki Almatani
doaj +1 more source
A Monte Carlo model of an agility head for a 10-MV photon beam
Objective: Modelling linear accelerator (linac) photon beams using the Monte Carlo (MC) technique is presently the most precise technique with which to calculate radiotherapy beam data.
Turki Almatani +2 more
doaj +1 more source
CARACTERIZACIÓN DOSIMÉTRICA DEL IRRADIADOR PRECLÍNICO X-RAD 320 A PARTIR DE SIMULACIONES MONTE CARLO
Se caracterizó el irradiador preclínico X-RAD 320 a partir de simulaciones Monte Carlo utilizando el código DOSXYZnrc a partir de una fuente puntual de radiación isotrópica que emite espectros de energía generados con el programa SpekCalc.
Luis E. Emiliani
doaj +1 more source
Effect of immobilization mask and beam energy on dose coverage to small joints in treating osteoarthritis with low-dose radiation therapy. [PDF]
Abstract Purpose Osteoarthritis (OA) is the most common form of arthritis, affecting over 32 million Americans. Low dose radiation therapy (LDRT) is being used to treat OA, including small joints. Treatment energies recommended include both orthovoltage and 6 MV photons.
Ding GX, Homann KL, Shinohara ET.
europepmc +2 more sources
Analisis Kurva Dose Volume Histogram (DVH) pada Teknik 3D Konformal dengan Metode Monte Carlo
Pemilihan sudut penyinaran yang tepat dalam terapi 3D konformal beberapa jenis kanker sangat menentukan keberhasilan pengobatan. Oleh karena itu, tujuan penelitian ini adalah untuk menganalisis dose volume histogram (DVH) teknik 3D konformal dengan ...
Sitti Yani
doaj +1 more source
Enhancing targeted doses: Low-energy photon lipiodol-enhanced radiotherapy (LEPERT) for liver cancer patients. [PDF]
Abstract Objectives This study proposes a novel approach, “Low‐energy photon Lipiodol‐Enhanced Radiotherapy” (LEPERT), for patients with liver cancer. Moreover, we evaluate the dose difference of the conventional treatment planning with 10 MV X‐ray beam (MV‐plan) and LEPERT.
Kawahara D.
europepmc +2 more sources
Se determinó un método para modelar el irradiador preclínico X-RAD 320 a partir de simulaciones Monte Carlo utilizando el código DOSXYZnrc a partir de una fuente puntual de radiación isotrópica que emite un espectro de energía generado con el programa ...
Luis E. Emiliani
doaj +1 more source