Results 51 to 60 of about 24,051 (235)
Tumbling Magnetic Microrobots for Targeted In Vivo Drug Delivery in the GI Tract
We introduce a microrobot design and integrated system for on‐demand targeted drug release in the gastrointestinal tract. The microrobot has an embedded magnet for actuation with external magnetic fields and is visualized in real time using ultrasound. It has two drug release ports sealed with a thermally sensitive wax. Local heating of the wax using a
Aaron C. Davis +7 more
wiley +1 more source
Continuum Robots in Surgery: From Engineering Design to Clinical Practice
The hyper‐redundant nature of continuum robot structures enables near‐infinite degrees of freedom leading to immense potential for medical applications. This review provides a historical background of continuum robots and novel ideas shaping their progress to current structural design, sensing technology, modeling techniques, and control methods.
Griffin Smith +6 more
wiley +1 more source
Purpose Practical training models can be a viable and effective educational tool that allows surgeons to acquire specific surgical techniques or skills. However, a suitable animal training model for reconstruction after a pancreaticoduodenectomy (PD) has
Jing-Rui Yang +9 more
doaj +1 more source
Flexible surgical robots are advancing minimally invasive interventions for cardiovascular diseases and cancer by enabling precise navigation through complex, submillimeter anatomical pathways. This review highlights recent innovations in actuation, bio‐integrated sensing, AI‐assisted control, and friction‐reduction technologies, discusses current ...
Hermione Truong +14 more
wiley +1 more source
Longitudinal Morphomolecular Monitoring of Head and Neck Carcinogenesis
A miniaturized endoscopic probe that integrates Raman spectroscopy and optical coherence tomography, enabling simultaneous molecular and structural imaging of living tissue, was developed. Applied longitudinally in a mouse model of head and neck cancer, the system tracks disease progression from precancerous lesions to invasive cancer.
Jianrong Qiu +7 more
wiley +1 more source
BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) remains a challenge for endoscopists in patients with surgically altered anatomy of the upper gastrointestinal tract.
S Cho +5 more
doaj +1 more source
Selenium Nanoparticles Selectively Target KRAS G13D to Inhibit Colorectal Cancer
The mechanisms of SeNPs therapy in cancer treatment, encompass three parallel actions: (1) seleno‐amino acids, key metabolites, upregulate GPX2 expression, thereby inhibiting tumor metastasis via the GPX2‐HIF1α‐VEGF signaling pathway; (2) selenite (SeO32−), an inorganic metabolite, forms hydrogen bonds with amino acid residues 13–17 of the KRAS G13D ...
Xiaoting Liu +13 more
wiley +1 more source
The joint capsule of the knee joint is attached to the edges of various articular surfaces and is thin and loose. Therefore, ligament reinforcement is needed to protect the knee joint and increase the stability of the joint.
Shunchao Zhang
doaj +1 more source
Review of Gastrointestinal Capsule Robots: Materials, Actuation, Diagnostics, and Therapeutics
This review examines gastrointestinal capsule robots through a systems engineering lens, covering shell materials, actuation and localization strategies, diagnostic modalities, therapeutic interventions, and commercialization status. By mapping the complete technological chain from fabrication to clinical deployment, this work identifies critical gaps ...
Zengsheng Li +8 more
wiley +1 more source
Useful of proximal gastrectomy with double-tract reconstruction in preventing glucose spikes
Volatile glucose levels after gastrectomy induce dumping syndrome, which adversely affects patient quality of life. This study aimed to evaluate the glycemic variability of proximal gastrectomy with double-tract reconstruction (PGDTR) as a function-preserving procedure.This study used a continuous glucose monitoring (CGM) system to record glycemic ...
Daisuke Fujimoto +3 more
openaire +3 more sources

