Results 91 to 100 of about 1,847,691 (292)

Double lumen endobronchial tube intubation: lessons learned from anatomy

open access: yesBMC Anesthesiology
Background Double lumen endobronchial tubes (DLTs) are frequently used to employ single lung ventilation strategies during thoracic surgical procedures. Placement of these tubes can be challenging even for experienced clinicians.
Robert B. Cameron   +4 more
doaj   +1 more source

Double lumen aortic arch in association with tetralogy of fallot [PDF]

open access: yes, 2006
Article regarding a patient, an 11-month-old girl born with Cornelia de Lange syndrome and tetralogy of Fallot, who underwent placement of a right modified Blalock-Taussig shunt as a neonate.peer ...
Farra, H., Johnston, Troy Alan
core  

Cross‐Scale Hierarchical Targeted Delivery System Based on Small‐Scale Magnetic Robots

open access: yesAdvanced Robotics Research, EarlyView.
This article reviews a cross‐scale hierarchical targeted delivery system that integrates magnetic continuum robots and magnetic microrobots. By combining rapid long‐range navigation with precise microscale targeting, the system overcomes key limitations of single‐scale approaches.
Junjian Zhou   +4 more
wiley   +1 more source

Functional Fibers in Soft Robotics: Advances in Material, Structural, and Systemic Tactics

open access: yesAdvanced Robotics Research, EarlyView.
Fiber‐form robotic systems offer a scalable pathway toward embodied intelligence in soft robotics. This review surveys functional fibers as material, structural, and systemic elements, highlighting advances in responsive materials, architectural programing, and fabrication strategies.
Joonhee Won   +5 more
wiley   +1 more source

LEFT DOUBLE LUMEN ENDOTRACHEAL TUBE: BRONCHOSCOPIC FINDING AFTER CONFIIRMATION OF CORRECT POSITION OF TUBE WITH AUSCULTATION

open access: yesPakistan Armed Forces Medical Journal, 2020
Objective: To determine the frequency of malposition of left sided double lumen endotracheal tube with fiber-optic bronchoscope after its correct positioning by auscultation. Study Design: Prospective observational study.
Liaquat Ali, Saira Mahboob, Umer Ali
doaj   +2 more sources

Curious case of pediatric one-lung ventilation with two endotracheal tubes: A case report

open access: yesAnnals of Cardiac Anaesthesia
One-lung ventilation is indicated during thoracic surgery for visualization and exposure of surgical site. It is achieved with bronchial blockers, double-lumen endobronchial tube, single-lumen endotracheal tubes and Univent tube for infants and children.
Lalit Jha   +3 more
doaj   +1 more source

Youngstown Sheet and Tube Company's Campbell Works mud gun

open access: yes, 1930
Mud gun in the cast house at the Youngstown Sheet and Tube Company's Campbell Works, East Youngstown (Campbell), Ohio. The mud gun, also know as a clay gun, closed the tapping hole when the casting was completed.
Youngstown Sheet and Tube Company
core  

Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare

open access: yesAdvanced Robotics Research, EarlyView.
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin   +3 more
wiley   +1 more source

Double-lumen Endotracheal Tube Insertion under Guiding of Peel-away® Introducer - ⁣ A case report ⁣-

open access: yes, 2006
Intubation of a double-lumen endotracheal tube (DLT) can be more difficult than a single-lumen endotracheal tube in difficult airways. Peel-away® introducer is used in urological procedures.A 54-year- old man undergoing right lung lobectomy could not be ...
남순호
core  

Attomolar Detection of HIV‐1 With Label‐Free RCA‐rCRISPR on Smartphone

open access: yesAdvanced Science, EarlyView.
A new diagnostic strategy integrating rolling circle amplification (RCA) with a plasmid reporter–based ratiometric CRISPR (rCRISPR) system was developed to detect unfragmented HIV genomes with single‐digit attomolar sensitivity. The method quantifies targets using the plasmid relaxation ratio and employs a smartphone‐based mini‐gel device to enable ...
Noor Mohammad   +12 more
wiley   +1 more source

Home - About - Disclaimer - Privacy