Results 111 to 120 of about 7,572 (233)
Predictive current control(PCC) scheme of doubly-fed induction generator(DFIG) system under unbalanced power grid is obtained by discretizing the mathematical model of rotor side converter(RSC) and grid side converter(GSC) of DFIG in the two-phase ...
SHENG Jianke +5 more
doaj
Dynamic modelling of wind turbine and power system for fault ride-through analysis [PDF]
This paper presents a Simulink model of a wind power system for the holistic analysis of wind turbine and power grid during grid faults, aiming to investigate wind turbine Fault Ride-Through performance.
Anaya-Lara, Olimpo +2 more
core
ANALYSIS OF NEUTRAL MODE SELECTION CRITERIA FOR DISTRIBUTION NETWORKS OF OPEN PIT MINES [PDF]
The effectiveness of any type of network neutral mode operation is determined by the appropriate technical and economic conformity of the uninterrupted power supply to consumers, the amount of capital investment and operating costs.
GREBENIUK, Andrii +3 more
core
Study of Doubly Fed Induction Generator (DFIG) Performance by Modeling & Simulation
Abstract Recently, there is a growing interest in wind turbine-generated electrical energy as a promising renewable energy source.Due to their outstanding performance quality, induction or asynchronous generators are currently regarded as one of the best electrical machine types that can work with wind turbines.
Omran Alabed Alkhamıs +5 more
openaire +1 more source
Modelling of doubly fed induction generator connected with a wind turbine [PDF]
There has been a tremendous rise in the use of the renewable energy resources. Global wind energy capacity soared by a fifth to 238GW at the end of 2011. India is the 5th largest player globally, accounted for 16 GW.
Sethi, Suchit Kumar, Suman, Ganesh Kumar
core
International audienceIn last decades, renewable energy resources are considered as an alternative energy resource to the world's excessive energy demand. An extremely abundant and promising source of energy exists in oceans. Currently, there are several
Benalia, Atallah +2 more
core +2 more sources
Enhanced fault diagnosis of DFIG converter systems [PDF]
Aboushady, Ahmed A. +2 more
core +1 more source
FAULT RIDE-THROUGH CAPABILITY AND DAMPING IMPROVEMENT IN DFIG [PDF]
Doubly-fed induction generator wind turbine is susceptible to faults and requires crowbar protection. When the crowbar is triggered, the rotor is short circuited over the crowbar impedance.
Dolara, Alberto +5 more
core
A discussion about a start-up procedure of a doubly-fed induction generator system [PDF]
The present work proposes a start-up procedure for a doubly-fed induction generator (DFIG) driven by a wind turbine. In the DFIG topology the stator is connected direct to the grid while the rotor is connected to a back-to-back converter.
Da Silva, J. L. +4 more
core

