Results 81 to 90 of about 7,720 (229)
A GEDMM is proposed to represent the MIWPS as multiple VSISs and model each of them as the VTDS2M whose unknown parameters are identified with the proposed hybrid optimized square root cubature Kalman filter (HOSRCKF). To solve the issues that the physical meanings of existing short circuit ratios (SCRs) are unclear and the critical values of existing ...
Mengxian Sun +3 more
wiley +1 more source
Preventive Control Considering Stability Constraints for Repeated Low Voltage Ride Through Events
This paper proposes a voltage stability preventive control strategy that accounts for repeated low‐voltage ride‐through characteristics. The method first partitions the system and constructs a short‐term voltage stability assessment index that effectively incorporates repetitive LVRT events, while offline generating a corresponding set of anticipated ...
Zhichong Cao +5 more
wiley +1 more source
Improved DFIG Capability during Asymmetrical Grid Faults [PDF]
In the wind power application, different asymmetrical types of the grid fault can be categorized after the Y/d transformer, and the positive and negative components of a single-phase fault, phase-to-phase fault, and two-phase fault can be summarized. Due
Blaabjerg, Frede, Zhou, Dao
core +2 more sources
Cyber‐Resilient MMC‐MTDC Stability via Robust Observer Design for Wind‐Integrated Grids
This paper proposes a stochastic stabilising control method, based on a Markov jump model (MJM), to comprehensively address stability challenges in modular multilevel converter‐based multi‐terminal direct current (MMC‐MTDC) systems due to communication network disturbances.
Mohsen Darabian +5 more
wiley +1 more source
An Accurate Forced Oscillation Location and Participation Assessment Method for DFIG Wind Turbine
With the integration of wind energy, the widely used doubly fed induction generator wind turbines (DFIG-WT) could induce Power System forced oscillations (FOs), which threaten the safety of power grid.
Jiaxing Lei +4 more
doaj +1 more source
Small signal stability analysis of doubly fed induction generator including SDBR [PDF]
This paper presents small signal stability analysis of a doubly fed induction generator (DFIG) based wind farm including series dynamic braking resistor (SDBR) connected at the stator side.
15th International Conference on Electrical Machines and Systems, ICEMS 2012 +4 more
core
To enhance grid stability and resilience in high renewable energy scenarios, this research proposes a cascaded control optimization framework guided by a novel dynamic resilience metric. Validated on a representative Australian grid, the framework significantly reduced voltage overshoot and extended fault clearing times, offering a robust solution for ...
Sadnan Sakib +4 more
wiley +1 more source
A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator [PDF]
Wind energy has become one of the most important and promising sources of renewable energy, which demands additional transmission capacity and better means of maintaining system reliability.
Arindya, R. (Radita)
core
This study introduces a novel framework integrating distributed sensor networks with advanced machine learning, utilising physics‐informed neural networks (PINNs) to enhance predictive maintenance and performance optimisation for wind turbines and solar farms, achieving an 87% failure prediction accuracy with a 14‐day lead time.
Nasir Muhamad +5 more
wiley +1 more source
This paper is concerned with behavior analysis and improvement of wind turbines with Doubly Fed Induction Generator (DFIG) when using a new fractional-order control strategy during wind variations.
M. Hosseinabadi, H. Rastegar
doaj