Results 201 to 210 of about 31,791 (255)
Some of the next articles are maybe not open access.
Critical clearing time of doubly fed induction generator
2005 IEEE Russia Power Tech, 2005A detailed model of grid-connected doubly-fed induction generator (DFIG) suitable for fault analysis is presented. 5th order model of wound rotor induction machine together with a two-mass model of the mechanical drive-train is employed to investigate transient voltage stability of integrated wind turbine.
Babak Badrzadeh, S. K. Salman
openaire +1 more source
State Observer for Doubly-fed Induction Generator
2017POWER ELECTRONICS AND DRIVES; ISSN 2451 ...
Blecharz, Krzysztof +2 more
openaire +1 more source
Optimal Efficiency Control in a Wind System With Doubly Fed Induction Generator
IEEE transactions on power electronics, 2019This paper proposes an optimal efficiency control scheme for a wind system with doubly fed induction generator (DFIG). The suggested control scheme combines loss minimization (LM) in the DFIG and maximum power point tracking (MPPT) in the wind turbine ...
N. Karakasis +4 more
semanticscholar +1 more source
Reactive Capability Limitations of Doubly-fed Induction Generators
Electric Power Components and Systems, 2009Abstract In the new electricity grid code, reactive power generation by wind farms, which must operate similarly to other conventional power plants, is a major concern during both steady-state and fault conditions. This article presents the reactive power capability of a doubly-fed induction generator through the use of performance capability curves ...
Bharat Singh, S. N. Singh
openaire +1 more source
Cascaded doubly fed induction generator using PFC rectifiers
2009 Compatability and Power Electronics, 2009Variable speed cascaded doubly fed induction generators (CDFIG) have been recently proposed to apply in renewable energy generation systems i.e. small hydropower plants, windmills, shaft generators of vessels and embedded applications. CDFIG requires lower maintenance than DFIG due the absence of slip rings and brushes.
Marek Adamowicz +2 more
openaire +1 more source
Renewable Energy, 2018
This paper presents a new approach to address the issue of the frequency deviations induced by the fluctuating power injected into the grid by doubly-fed induction generator based wind turbines in a weak or isolated power system that is based in a ...
D. Ochoa, S. Martinez
semanticscholar +1 more source
This paper presents a new approach to address the issue of the frequency deviations induced by the fluctuating power injected into the grid by doubly-fed induction generator based wind turbines in a weak or isolated power system that is based in a ...
D. Ochoa, S. Martinez
semanticscholar +1 more source
Novel crowbar system in doubly fed induction generators
2015 IEEE Eindhoven PowerTech, 2015Nowadays, grid code requirements demand that wind energy converters (WEC) remain connected to the grid during grid faults and contribute to the voltage support, in the same way as conventional power plants. WEC which are capable of ridding through grid faults providing voltage and reactive power support are connected to the grid via electronic power ...
Dario Lafferte +2 more
openaire +1 more source
ISA transactions, 2019
A new control strategy based on the root tree optimization (RTO) is presented in order to reduce the chattering phenomena in active and reactive powers, and to minimize the harmonic currents which appear mostly at the level of the rotor side converter ...
A. Benamor +3 more
semanticscholar +1 more source
A new control strategy based on the root tree optimization (RTO) is presented in order to reduce the chattering phenomena in active and reactive powers, and to minimize the harmonic currents which appear mostly at the level of the rotor side converter ...
A. Benamor +3 more
semanticscholar +1 more source
Harmonic analysis of a Doubly Fed Induction Generator
IEEE PES T&D 2010, 2010The aim of this paper is to develop a framework for analysis of harmonics in a Doubly Fed Induction Generator (DFIG) caused by non-sinusoidal conditions in the rotor as well as unbalance in stator. Non-sinusoidal rotor voltages are decomposed into harmonic components and their corresponding sequences are identified.
null Lingling Fan +2 more
openaire +1 more source
IEEE transactions on industry applications, 2019
Doubly-fed induction generator (DFIG)-based wind turbine generators need to be connected back to integrated power grid after tripping due to disturbances and emergencies in power grid. Re-connection can cause switching transients which may affect overall
Abilash Thakallapelli +3 more
semanticscholar +1 more source
Doubly-fed induction generator (DFIG)-based wind turbine generators need to be connected back to integrated power grid after tripping due to disturbances and emergencies in power grid. Re-connection can cause switching transients which may affect overall
Abilash Thakallapelli +3 more
semanticscholar +1 more source

