Results 111 to 120 of about 7,719 (230)
Structural integrity of a Doubly Fed Induction Generator (DFIG) of a wind power system (WPS)
Abstract Improving the electricity production and enhancing the overall and the quality of the electrical grid are obligatory to reach nowadays clients requirements regarding the quality of energy. Thus, the integration of green power such us solar, Wind Power Systems (WPS) and biomass has changed the energy world face, and contributed to satisfy the
Mohammed Ezzahi +2 more
openaire +1 more source
Electric Generators Fitted to Wind Turbine Systems: An Up-to-Date Comparative Study
International audienceThis paper describes a comparative study allowing the selection of the most appropriate innovative structures for electrical machines for a wind turbine system. This study is based on an exhaustive review of the state of the art and
Benbouzid, Mohamed +3 more
core +1 more source
ANALYSIS OF NEUTRAL MODE SELECTION CRITERIA FOR DISTRIBUTION NETWORKS OF OPEN PIT MINES [PDF]
The effectiveness of any type of network neutral mode operation is determined by the appropriate technical and economic conformity of the uninterrupted power supply to consumers, the amount of capital investment and operating costs.
GREBENIUK, Andrii +3 more
core
FAULT RIDE-THROUGH CAPABILITY AND DAMPING IMPROVEMENT IN DFIG [PDF]
Doubly-fed induction generator wind turbine is susceptible to faults and requires crowbar protection. When the crowbar is triggered, the rotor is short circuited over the crowbar impedance.
Dolara, Alberto +5 more
core
International audienceIn last decades, renewable energy resources are considered as an alternative energy resource to the world's excessive energy demand. An extremely abundant and promising source of energy exists in oceans. Currently, there are several
Benalia, Atallah +2 more
core +2 more sources
Impact of df/dt Inertia Control on Doubly Fed Induction Generator Type Wind Turbine
the supplemental df/dt control is the common method for wind power generation to support system inertial response. This paper investigates the impact of the df/dt inertia controller on doubly fed induction generator (DFIG) type wind turbine.
Hua Huang, Xin Tao, Xu Tian, Fei Peng
doaj +1 more source
In this paper, a fractional order active (P) and reactive (Q) power controller of doubly fed induction generator (DFIG) is developed and it performance is demonstrated using hardware in loop (HIL) testing with Opal RT OP4510 real-time platform.
Shivaji Ganpat Karad +6 more
doaj +1 more source
Minimization of current stress on the grid synchronization of doubly-fed induction generators for wind power generation [PDF]
Author name used in this publication: S. L. HoAuthor name used in this publication: K. W. E.
Cheng, KWE, Ho, SL, Wong, KC
core
Predictive current control(PCC) scheme of doubly-fed induction generator(DFIG) system under unbalanced power grid is obtained by discretizing the mathematical model of rotor side converter(RSC) and grid side converter(GSC) of DFIG in the two-phase ...
SHENG Jianke +5 more
doaj
Lyapunov-Based Robust Power Controllers for a Doubly Fed Induction Generator
In this work, a robust nonlinear control technique of a doubly fed induction generator (DFIG) intended for wind energy systems has been proposed. The principal idea in this article is to decouple the active and reactive power of the DFIG with high ...
Y. Djeriri
doaj

