Results 21 to 30 of about 2,865,152 (246)
Understudied factors in drug‐coated balloon design and evaluation: A biophysical perspective
Drug‐coated balloon (DCB) percutaneous interventional therapy allows for durable reopening of the narrowed lumen via physical tissue expansion and local anti‐restenosis drug delivery, providing an alternative to traditional uncoated balloons or a ...
Tarek Shazly +5 more
doaj +2 more sources
BackgroundDrug coated balloons (DCB) with paclitaxel (Ptx) dose of 2-3.5 μg/mm2 balloon surface inhibit restenosis with different effectiveness and duration of success. A clinical dose finding study is not known for any of the currently marketed products.
Ole Gemeinhardt +3 more
doaj +2 more sources
Assessment of Paclitaxel Drug-Coated Balloon Only Angioplasty in STEMI [PDF]
Background: Primary percutaneous coronary intervention (pPCI) with drug-eluting stents (DES) has emerged as the standard of care, but stent-related events have persisted.
Eccleshall, Simon C +18 more
core +5 more sources
Welcoming Novelty in the Treatment of Coronary Artery Disease: FDA Approves the Use of Drug-Coated Balloon for Angioplasty. [PDF]
The US FDA has approved the use of drug‐coated balloons (DCBs) for treating in‐stent restenosis, a major challenge in coronary artery disease management. The AGENT IDE Trial, a multicenter randomized study, evaluated the efficacy of the paclitaxel‐coated balloon catheter, demonstrating reduced rates of target lesion failure, myocardial infarction, and ...
Hasan AH, Abid MA, Nazir A.
europepmc +2 more sources
ObjectivesThe aim of this all-comers registry study was to investigate the technical success, clinical efficacy, and safety of a drug-coated balloon (DCB) with paclitaxel combined with citrate ester excipient (CEE) in percutaneous coronary intervention ...
Jerry Tervo +2 more
doaj +1 more source
Supplemental material, sj-tiff-1-jet-10.1177_15266028231214167 for Effect of High-Dose Drug-Coated Balloon Repetition After Drug-Coated Balloon Failure by Yusuke Tomoi, Mitsuyoshi Takahara, Yoshimitsu Soga, Taichi Hirano, Kazuki Tsunoda, Tomonori Katsuki
Tomonori Katsuki (7298834) +6 more
core +1 more source
QUESTION: What is the evidence available on the use of drug-coated balloons (DCB) in the de novo lesion setting? ANSWER: The use of DCB to treat de novo lesions is the most compelling argument regarding this technology, an area that has advanced ...
Bernardo Cortese
doaj +1 more source
Background Endovascular revascularization has established as the first-line therapy of femoropopliteal artery disease. Paclitaxel-coated balloon angioplasty proved to be superior to plain old balloon angioplasty (POBA) regarding prevention of restenosis ...
Ulf Teichgräber +6 more
doaj +1 more source
Time course of vascular response after an a priori strategy of bare metal stent implantation post-dilated with a paclitaxel-coated balloon: Implementation of a three-dimensional analysis algorithm with optical coherence tomography [PDF]
Background: An a priori combined therapy of a bare metal stent post-dilated with a paclitaxel- -coated balloon (PCB) was investigated with optical coherence tomography (OCT) at 2 and 6 months regarding vessel response.
Gassdorf, Johannes; University Clinic of Jena, 1st Medical Dept., Division of Cardiology, Erlanger Allee 101, 07740 Jena +7 more
core +1 more source
Drug-coated balloon angioplasty for severe pulmonary vein stenosis resulting from cryoballoon ablation for atrial fibrillation [PDF]
We performed a drug-coated balloon (DCB) angioplasty for severe pulmonary vein (PV) stenosis resulting from cryoballoon ablation for atrial fibrillation. Three and fourteen months after the angioplasty, follow-up multidetector computed tomography did not
Soeki, Takeshi +81 more
core +1 more source