Results 71 to 80 of about 21,695 (218)

Drug‐Coated Balloons Versus Drug‐Eluting Stents or Plain Old Balloon Angioplasty: A Long‐Term in‐Stent Restenosis Study

open access: yesJournal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Background Balloon angioplasty with drug‐coated balloons (DCBs) is frequently used during percutaneous coronary intervention for in‐stent restenosis. Despite its frequent use, there is a lack of long‐term data on the efficacy of DCB angioplasty.
Sacharias von Koch   +8 more
doaj   +1 more source

Development and Micro Manufacturing of Coronary Stents in Hungary [PDF]

open access: yes, 2006
Revascularisation by endovascular implant (stent) has great importance in the treatment of coronary artery diseases. Stents are high-technology implants that are the creation of the knowledge of health sciences, physics, chemistry, material science and
Dobránszky, János   +3 more
core  

Clinical Impact of Angiographic Complications Occurring During Percutaneous Coronary Interventions

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background The clinical impact of different types of angiographic complications during elective PCIs remains largely unexplored. Aims To explore the incidence, management, and outcomes of angiographic complications by type and severity during non‐urgent, non‐CTO PCIs. Methods Clinical and procedural characteristics were prospectively collected
Emiliano Bianchini   +16 more
wiley   +1 more source

In-Stent Restenosis and a Drug-Coated Balloon: Insights from a Clinical Therapeutic Strategy on Coronary Artery Diseases

open access: yesCardiology Research and Practice, 2020
Coronary heart disease is a major cause of death and disability in developed countries. Stent implantation has become an efficacious treatment for a culprit lesion vessel of the coronary artery.
Dai-Min Zhang, Shaoliang Chen
doaj   +1 more source

A New 3-D automated computational method to evaluate in-stent neointimal hyperplasia in in-vivo intravascular optical coherence tomography pullbacks [PDF]

open access: yes, 2009
. Detection of stent struts imaged in vivo by optical coherence tomography (OCT) after percutaneous coronary interventions (PCI) and quantification of in-stent neointimal hyperplasia (NIH) are important.
Carlier, Stephane   +3 more
core   +1 more source

Excessive Ostial Stent Protrusion: Evaluation of Management Strategies and Clinical Outcomes of the Side Flap Technique

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Backgrounds Accurate stent positioning in aorto‐ostial lesions remains challenging due to complex three‐dimensional anatomy, lack of optimal fluoroscopic projections, and high rates of geographic miss. Stent overhang impairs guide catheter re‐engagement and complicates future revascularization.
Gregor Leibundgut   +7 more
wiley   +1 more source

Drug-eluting balloon catheters for lower limb peripheral arterial disease: the evidence to date

open access: yesVascular Health and Risk Management, 2016
Mohamed Barkat,1 Francesco Torella,1 George A Antoniou2 1Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, 2Department of Vascular and Endovascular Surgery, The Royal Oldham Hospital, Pennine Acute Hospitals NHS
Barkat M, Torella F, Antoniou GA
doaj  

Characterisation of the mechanobiology of stents in vitro [PDF]

open access: yes, 2014
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the ...
4th Micro and Nano Flows Conference (MNF2014)   +6 more
core  

Successful Management of a Complex Coronary Bifurcation Lesion in Acute Coronary Syndrome Using a Free‐Metal Approach

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT We present the case of a 56‐year‐old male with non‐ST elevation myocardial infarction (NSTEMI) and a complex thrombotic lesion at the ostial left circumflex artery (LCX), extending into bifurcating marginal branches. Due to the high risk of side branch occlusion, a stentless strategy using thrombus aspiration, the reverse wire technique, and ...
Flavius‐Alexandru Gherasie   +1 more
wiley   +1 more source

Examination of the coatings of coronary stents [PDF]

open access: yes, 2006
In our study the main properties of coated coronary stents are shown, such as foreshortening, recoil, surface features and failures and the expansion properties. The types and the effects of active and passive coatings are introduced.
Bognár, Eszter   +3 more
core  

Home - About - Disclaimer - Privacy