Results 31 to 40 of about 7,742,937 (292)

Research on distribution of winding leakage magnetic field of three-phase dry type transformer under short-circuit condition

open access: yesEnergy Reports, 2023
Leakage flux magnitude and pattern greatly affect transformer short-circuit resistance. In this paper, finite element calculations and experimental measurements is used to calculate the leakage magnetic field of a transformer.
Tiannan Meng   +5 more
doaj   +1 more source

Bridging in contaminated transformer oil under DC and AC electric field

open access: yes, 2013
One of the key components in high voltage transmission and distribution systems are power transformers and their consistent operation is of utmost importance to energy utilities and users.
Wilson, G   +9 more
core   +1 more source

Peripheral lysosomes recruit PLEKHG3 to focal adhesions and restrain protrusion dynamics

open access: yesFEBS Letters, EarlyView.
Proximity‐dependent labeling at the LAMTOR complex revealed the Rho GEF PLEKHG3 as a lysosome‐proximal protein directing the study toward the influence of lysosome positioning on actin dynamics and cell motility. We show that PLEKHG3 colocalizes with lysosomes at focal adhesion sites and observe that forced peripheral dispersion of lysosomes hinders ...
Rainer Ettelt   +8 more
wiley   +1 more source

Convolutional Neural Network-Based Transformer Fault Diagnosis Using Vibration Signals

open access: yesSensors, 2023
Fast and accurate fault diagnosis is crucial to transformer safety and cost-effectiveness. Recently, vibration analysis for transformer fault diagnosis is attracting increasing attention due to its ease of implementation and low cost, while the complex ...
Chao Li   +5 more
doaj   +1 more source

Golgi enzymes are retrieved from the plasma membrane to the trans‐Golgi network

open access: yesFEBS Letters, EarlyView.
Golgi enzymes are traditionally considered resident proteins retained within the Golgi apparatus. Here, we demonstrate that a subset transiently reaches the cell surface and is subsequently retrieved to the trans‐Golgi network via retrograde transport. Using a nanobody‐based toolkit, we uncover a dynamic trafficking cycle of several Golgi enzymes.
Dominik P. Buser, Tina Junne
wiley   +1 more source

Thermal effects due to harmonics on dry-type transformers: Impact of filters and phase angles

open access: yesMeasurement: Energy
Integrating distributed energy sources has introduced significant challenges to power quality. One notable issue is the generation of harmonic distortions by power electronics converters, which significantly affect the performance and efficiency of power
Mateus Caruso Costa   +3 more
doaj   +1 more source

Ligand‐dependent transcriptional heterogeneity in cell cycle gene expression delays G1/S entry

open access: yesFEBS Letters, EarlyView.
EGF and HRG induce distinct G1/S progression programs in ErbB2‐amplified BT474 breast cancer cells. Despite activating the potent ErbB2–ErbB3 heterodimer, HRG does not accelerate cell‐cycle entry. Instead, EGF promotes earlier restriction‐point passage via ERK–FOS signaling, whereas HRG activates the AKT–MYC axis, driving transcriptional heterogeneity ...
Ririn Rahmala Febri   +5 more
wiley   +1 more source

Insulation Online Monitoring Method for Dry-Type Current Transformers Based on Virtual Voltage

open access: yesEnergies
To improve the accuracy of insulation state online monitoring for capacitive dry-type current transformers (CTs) and to address the limitations of traditional methods relying on potential transformer (PT) voltage signals and reference devices, a virtual ...
Junjie Zhang   +6 more
doaj   +1 more source

Temperature distribution in ventilated dry-type transformer windings [PDF]

open access: yes, 2008
Temperature is an important factor when designing a transformer since thermal stress deteriorates electrical insulation and results in the failure of the transformer.
Lee, Moonhee
core  

Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil

open access: yes, 2015
Analysis of real operating condition revealed that HVDC transformers experience combined effect of DC biased AC electric field. The dynamics of pressboard particle in contaminated transformer oil under the influence of DC, AC and DC biased AC electric ...
Mahmud, S.   +4 more
core   +1 more source