Results 141 to 150 of about 1,242,170 (229)

Screen-Printed Dry Electrodes: Basic Characterization and Benchmarking

open access: yes, 2020
The electrical performance of screen‐printed dry electrodes on thermoplastic polyurethane substrates are evaluated according to their conformance to international standards, skin‐electrode impedance, and ability to gather high quality electrocardiograms.
Brand, J. van den   +4 more
core  

3D‐Printed Gradient Shape‐Memory Strain Sensors With Rewritable Gauge Factors

open access: yesAdvanced Functional Materials, EarlyView.
A 3D‐printed shape‐memory strain sensor combines thermomechanical programming with gradient architectural design. Preset strain rewrites the gauge factor (GF), while the gradient geometry amplifies the response through strain redistribution. Reprogrammable sensitivity enables the same sensor to detect weak pulse signals and monitor large‐amplitude ...
Xuan Zhang   +10 more
wiley   +1 more source

Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment. [PDF]

open access: yesMicromachines (Basel)
Alokaily AO   +10 more
europepmc   +1 more source

Magneto‐Ionic Devices With Polymer‐Based Electrolytes

open access: yesAdvanced Functional Materials, EarlyView.
Polymer electrolytes are introduced for magneto‐ionic devices based on hydroxide and hydrogen ions. The magneto‐ionic effect results in a pronounced voltage‐controlled variation of coercivity in both devices. The switching speed is in the range of 100 ms.
Markus Gößler   +3 more
wiley   +1 more source

Configuration‐Encoded Cell Alignment by Light‐Gated Silicon Photovoltaic Microcell Arrays

open access: yesAdvanced Functional Materials, EarlyView.
Light‐gated silicon photovoltaic microcells convert pulsed illumination into localized electrical cues. Arranging otherwise similar microcells into four‐lobed, six‐lobed, or circular patterns directs fibroblasts into corresponding local arrangements without wired stimulation.
Yifan Tao   +7 more
wiley   +1 more source

Engineering Concentration‐Dependent Intravitreal Mobility via Cyclic Arginine‐Enriched Nanocarrier Surface Modification: In Vivo Proof‐of‐Concept in a Porcine Large Animal Model

open access: yesAdvanced Healthcare Materials, EarlyView.
In this study, Hammer et al. highlight cyclic‐arginine surface engineering as a highly biocompatible, controllable, and concentration‐dependent regulator of intravitreal nanoparticle mobility in vivo in a translational large animal model. The cyclic arginine surface‐modification supports the development of next‐generation biomaterials for long‐acting ...
Maximilian Hammer   +12 more
wiley   +1 more source

Profiled Wet Spinning of Polyurethane Composites for Soft Dry Electrodes in Transcutaneous Stimulation Applications. [PDF]

open access: yesMaterials (Basel)
Shokurov AV   +8 more
europepmc   +1 more source

Zwitterionic Polymer Coating Enabled Chronic Dopamine Sensing and Electrophysiology Recording in Free‐Moving Mice

open access: yesAdvanced Healthcare Materials, EarlyView.
Application of a zwitterionic poly(sulfobetaine methacrylate) (PSB) coating to microelectrode arrays and Ag/AgCl reference electrodes effectively inhibits biofouling and structural degradation. This strategy successfully enables simultaneous, long‐term electrophysiological recording and dopamine sensing in freely behaving mice, facilitating ...
Bingchen Wu   +5 more
wiley   +1 more source

NeuroVisio SyncPatch: A Skin‐Conformal Multimodal EMG–Motion Sensing Platform for Quantitative Neuromuscular Rehabilitation and Performance Monitoring

open access: yesAdvanced Healthcare Materials, EarlyView.
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy