Results 61 to 70 of about 2,637 (164)

Graft detachment rates in surgeon‐cut and pre‐cut tissue for DSAEK transported in different mediums

open access: yesActa Ophthalmologica, Volume 103, Issue 3, Page 281-288, May 2025.
Abstract Purpose To analyse graft detachment rates after Descemet stripping automated endothelial keratoplasty (DSAEK) using surgeon‐cut grafts and pre‐cut grafts transported in different mediums. Methods A retrospective study of graft detachment rates including 265 surgeries (240 patients) performed between 2019 and 2023.
Thorbjörg Olafsdottir   +4 more
wiley   +1 more source

Long‐term mental health outcomes after corneal transplantation and potential predictors: A multicentre prospective cohort study

open access: yesOphthalmic and Physiological Optics, Volume 45, Issue 2, Page 340-351, March 2025.
Abstract Introduction To evaluate the long‐term effect of corneal transplantation on mental health outcomes and to assess potential predictors of these outcomes. Methods For this multicentre prospective cohort study, patients awaiting corneal transplantation were recruited from 11 (academic) hospitals and eye clinics in the Netherlands. Participants (n 
E. B. M. Elsman   +11 more
wiley   +1 more source

Diagnosis of Donor Graft Partial Dislocation Behind the Iris After DSAEK With Anterior Segment OCT

open access: yes, 2010
A 65-year-old woman was referred with postoperative persistent corneal edema and interface fluid superiorly without dislocation of the donor button after Descemet's stripping automated endothelial keratoplasty (DSAEK).
Ide, Takeshi   +7 more
core   +1 more source

Comparison and Correlation of the Donor–Recipient Interface Changes and Visual Outcomes Between nDSEK and DSEK

open access: yesJournal of Ophthalmology, Volume 2025, Issue 1, 2025.
Purpose: This study aimed to compare the donor–recipient interface changes between non‐Descemet stripping endothelial keratoplasty (nDSEK) and Descemet stripping endothelial keratoplasty (DSEK) and assess their correlation with the postoperative best spectacle‐corrected visual acuity (BCVA).
Minghai Huang   +8 more
wiley   +1 more source

Safety Profile of Intraoperative Corneal Debridement in Descemet Membrane Endothelial Keratoplasty (DMEK)—A Retrospective Comparative Study

open access: yesJournal of Ophthalmology, Volume 2025, Issue 1, 2025.
Purpose To investigate the influence of intraoperative corneal debridement on postoperative outcomes in Descemet Membrane Endothelial Keratoplasty (DMEK). Methods This retrospective comparative study analyzed 3168 eyes that underwent DMEK between 2012 and 2024. Intraoperative corneal debridement was performed in 215 eyes (6.8%) to improve visualization
Sebastian Arens   +4 more
wiley   +1 more source

Frequency of Fb/MFb transdifferentiation in groups A and B before and after DSAEK.

open access: yes, 2013
Frequency of Fb/MFb transdifferentiation in groups A and B before and after DSAEK.
Naoyuki Morishige (459110)   +4 more
core   +1 more source

Descemet Membrane Endothelial Keratoplasty versus Descemet Stripping Automated Keratoplasty – Outcome of One Single Surgeon’s More Than 200 Initial Consecutive Cases

open access: yesClinical Ophthalmology, 2021
Christina Jansen,1 Madeleine Zetterberg1,2 1Department of Ophthalmology, Region Västra Götaland, Sahlgrenska University Hospital, Mölndal, Sweden; 2Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska ...
Jansen C, Zetterberg M
doaj  

Effect of venting incisions on graft attachment in Descemet's stripping automated endothelial keratoplasty

open access: yesJournal of Current Ophthalmology, 2018
Purpose: To investigate the impact of venting incisions on the adherence of graft to the recipient's stroma in Descemet's stripping automated endothelial keratoplasty (DSAEK). Methods: Fifty-six patients were enrolled in this study.
Masoumeh Mohebbi   +6 more
doaj   +1 more source

Intraocular pressure‐related side‐effects after endothelial keratoplasty

open access: yesActa Ophthalmologica, Volume 102, Issue 6, Page 674-682, September 2024.
Abstract Purpose To investigate circumpapillary retinal nerve fibre layer (RNFL) thickness, pupillary function and diameter after phacoemulsification and lens implantation alone or combined with endothelial keratoplasty (EK). Methods This study was a secondary analysis of data from a randomized, single‐masked trial, that included 72 patients with Fuchs'
Morten B. M. Madsen   +3 more
wiley   +1 more source

Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

open access: yesClinical Ophthalmology, 2015
Peter J Morgan-Warren, Walter Andreatta, Amit K Patel Department of Ophthalmology, Solihull Hospital, Heart of England NHS Foundation Trust, Birmingham, UK Purpose: Opacification of hydrophilic acrylic intraocular lenses (IOLs) is an emerging ...
Morgan-Warren PJ, Andreatta W, Patel AK
doaj  

Home - About - Disclaimer - Privacy