Results 21 to 30 of about 3,234 (215)

Optimal placement of DSTATCOM in distribution network based on load flow and voltage stability indices studies [PDF]

open access: yes, 2017
The power utilities are experiencing a new challenge as the demand for electrical power is increasing on a regular basis. This forced the existing networks operates closed to its stability limits.
Abd Rahim, Mohd Fitri   +5 more
core   +1 more source

Five-Level DSTATCOM for Power Quality Improvement Using Intelligent Controllers [PDF]

open access: yesE3S Web of Conferences
Addressing power quality issues is an important task for power engineers as a small disturbance in power system can initiate hefty disaster to the loads connected at user point.
Singh Satendra   +3 more
doaj   +1 more source

Reduced Sensor Based Control of PV-DSTATCOM with Switch Current Limiting Scheme

open access: yesEnergies, 2022
The work delineated in this paper deals with the reduced sensor-based operation of PV-DSTATCOM (Photovoltaic distribution static compensator) focusing on the voltage source inverter (VSI) switch current limiting control. In this study, the soft computing
Pragnyashree Ray   +2 more
doaj   +1 more source

Provision of high quality power supply in distribution networks with renewable energy sources [PDF]

open access: yes, 2011
Розглянуто особливості практичного застосування розроблених багатофункціональних засобів забезпечення надійного електропостачання і нормованих показників якості напруги в електричних мережах малих систем розподілу.
Жаркін, Андрій Федорович   +3 more
core   +1 more source

Providing of electromagnetic compatibility in local electric networks [PDF]

open access: yes, 2018
Розглянуто основні аспекти розробки принципів побудови параметричних та регульованих фільтросиметруючих пристроїв, а також гібридних фільтрокомпенсуючих перетворювачів на їх основі для забезпечення електромагнітної сумісності навантажень та комплексного ...
Жаркін, Андрій Федорович   +5 more
core   +1 more source

Compensation of Distribution System Voltage using DVR [PDF]

open access: yes, 2002
A dynamic voltage restorer (DVR) is a power-electronic controller that can protect sensitive loads from disturbances in the supply system. In this paper, it is demonstrated that this device can tightly regulate the voltage at the load terminal against ...
Ghosh, Arindam, Ledwich, Gerard
core   +2 more sources

DSTATCOM Control Algorithms: A Review

open access: yesInternational Journal of Power Electronics and Drive Systems (IJPEDS), 2012
The concept that an inverter can be used as a generalized impedance converter to realize either inductive or capacitive reactance has been widely used to mitigate power quality issues of distribution networks. One such device is the DSTATCOM which is connected in shunt at the load end. The heart of the DSTATCOM is a converter.
Ambarnath Banerji   +2 more
openaire   +1 more source

Strategic incorporation of DSTATCOM and distributed generations in balanced and unbalanced radial power distribution networks considering time varying loads

open access: yesEnergy Reports, 2023
The article focuses on the optimal planning of distribution static synchronous compensator (DSTATCOM) and distributed generation (DG) to minimize power losses, and simultaneously enhance the voltage profile, and voltage stability at various nodes of the ...
Muthukumar Kandasamy   +6 more
doaj   +1 more source

A multifunctional dynamic voltage restorer for power quality improvement [PDF]

open access: yes, 2018
Power quality is a major concern in electrical power systems. The power quality disturbances such as sags, swells, harmonic distortion and other interruptions have an impact on the electrical devices and machines and in severe cases can cause serious ...
Dung, Vo Tien   +2 more
core   +1 more source

Experimental analysis of DI-ZSI based DSTATCOM

open access: yesInternational Journal of Applied Power Engineering (IJAPE), 2023
This article presents the dual operation of distributed energy resources (DER) integrated impedance source inverter (DI-ZSI). The distribution grid, DER and variable nonlinear load are operating on two modes. In mode-1, power generated by the DER is zero or less then the load requirement and the inverter act as a voltage source inverter (VSI) for shunt
Jogeswara Sabat   +4 more
openaire   +1 more source