Results 41 to 50 of about 18,723 (229)
PURPOSE To compare and to combine iterative metal artifact reduction (MAR) and virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (DECT) for reducing metal artifacts from intracranial clips and coils.
Michels, Lars +17 more
core +1 more source
This study explored how effective nickel aluminide coatings are obtained in providing oxidation resistance applied to the Inconel 738 alloy, modeling with diffusion models. In the present study, kinetics and thermal behavior of the Inconel 738 alloy were studied by the low‐temperature thermoreactive aluminizing process, which was carried out at 625°C ...
Gozde Celebi Efe +4 more
wiley +1 more source
Performance Analysis of Abradable Coating Systems for Aircraft Gas Turbines
Three CoNiCrAlY/YSZ/MgAl2O4 abradable liner configurations on a nickel‐superalloy are evaluated by thermal‐gradient cycling and incursion tests. Laser ablation of the bondcoat and/or Y2O3‐stabilized ZrO2 (YSZ) intermediate layer increases mechanical interlocking and bonding for thick topcoats.
Hanna Heyl +4 more
wiley +1 more source
Failure strength of human vertebrae: prediction using bone mineral density measured by DXA and bone volume by micro-CT [PDF]
Significant relationships exist between areal bone mineral density (BMD) derived from dual energy X-ray absorptiometry (DXA) and bone strength. However, the predictive validity of BMD for osteoporotic vertebral fractures remains suboptimal.
Perilli, E. +7 more
core +1 more source
Selenium was incorporated into a sol–gel‐derived bioactive glass to enable sustained therapeutic ion release. The selenium‐containing glass preserved bioactivity while selectively inducing cytotoxicity in osteosarcoma cells and maintaining osteoblastic viability.
Breno Rocha Barrioni +7 more
wiley +1 more source
Approximate calibration method.
(a) The copper ring phantom was kept parallel and orthogonal to the rotary axis in the micro-CT scanner. The detector’s center point(U0, V0) was estimated approximately from the radiographic images.
Swathi Lakshmi Balasubramanian (12078093) +1 more
core +1 more source
Phase Field Failure Modeling: Brittle‐Ductile Dual‐Phase Microstructures under Compressive Loading
The approach by Amor and the approach by Miehe and Zhang for asymmetric damage behavior in the phase field method for fracture are compared regarding their fitness for microcrack‐based failure modeling. The comparison is performed for the case of a dual‐phase microstructure with a brittle and a ductile constituent.
Jakob Huber, Jan Torgersen, Ewald Werner
wiley +1 more source
Investigation of Imaging Capabilities for Dual Cone-Beam Computed Tomography [PDF]
A bench-top dual cone-beam computed tomography (CBCT) system was developed consisting of two orthogonally placed 40x30 cm2 flat-panel detectors and two conventional X-ray tubes with two individual high-voltage generators sharing the same rotational axis.
Li, Hao
core
PIE-ARNet: Prior Image Enhanced Artifact Removal Network for Limited-Angle DECT
International audienceDual-energy computed tomography (DECT) is of great clinical significance because it can simultaneously visualize the internal structure of the scanned object and provide material-specific information.
Zhang, Yikun +8 more
core +1 more source
Multimodal Data‐Driven Microstructure Characterization
A self‐consistent autonomous workflow for EBSP‐based microstructure segmentation by integrating PCA, GMM clustering, and cNMF with information‐theoretic parameter selection, requiring no user input. An optimal ROI size related to characteristic grain size is identified.
Qi Zhang +4 more
wiley +1 more source

