Results 81 to 90 of about 18,723 (229)
Image quality of low-energy pulmonary CT angiography: comparison with standard CT.
The purpose of this article is to prospectively compare visualization of central and peripheral pulmonary arteries on simultaneously acquired low-energy and standard pulmonary CT angiography.Thirty-three consecutive patients (20 women and 13 men; mean ...
Bogot, NR;Fingerle, A;Shaham, D;Nissenbaum, I;Sosna, J
core
Spectrally joint reconstruction and material classification from multi-energy CT
X-ray computed tomography (CT) is a popular technique for non-destructive examination of the interior of an object in medical diagnosis and security applications. This technique can reconstruct a high-resolution three-dimensional (3D) image of the object
Jumanazarov, Doniyor
core
In MOCVD MoS2 memristors, a current compliance‐regulated Ag filament mechanism is revealed. The filament ruptures spontaneously during volatile switching, while subsequent growth proceeds vertically through the MoS2 layers and then laterally along the van der Waals gaps during nonvolatile switching.
Yuan Fa +19 more
wiley +1 more source
Integration of Low‐Voltage Nanoscale MoS2 Memristors on CMOS Microchips
This article presents the first monolithic integration of nanoscale MoS2‐based memristors into the back‐end‐of‐line of foundry‐fabricated CMOS microchips in a one‐transistor‐one‐resistor (1T1R) architecture. The MoS2‐based 1T1R cells exhibit forming‐free, nonvolatile resistive switching with ultra‐low operating voltages, low cycle‐to‐cycle variability ...
Jimin Lee +16 more
wiley +1 more source
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim +6 more
wiley +1 more source
Preliminary investigations on high energy electron beam tomography
In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images ...
Hoppe, Dietrich +2 more
core +1 more source
A 3D anisotropic hydrogel derived from heart extracellular matrix guides cytoskeletal alignment and nuclear remodeling in reprogrammed cardiomyocyte‐like cells. This study reveals how matrix alignment modulates nuclear envelope dynamics and chromatin state, triggering transcriptional and functional maturation.
Seung Ju Seo +7 more
wiley +1 more source
Omnipolar Magnetic Field Detection by Superlattice‐Based Hall Sensor
Magnetic‐field‐induced electronic switching is demonstrated in unit‐cell‐engineered La0.7Sr0.3MnO3–BiFeO3 superlattices. Distinct substrate terminations modify magnetic and transport properties. Hall resistance measurements show omnipolar, hysteretic anomalous Hall switching above the Curie temperature, arising from Fe─Mn interfacial exchange, enabling
Mark Huijben +6 more
wiley +1 more source
Fast KV-Switching and Dual-Layer Flat-Panel Detector Enabled Cone-Beam CT Joint Spectral Imaging
Purpose: Fast kV-switching (FKS) and dual-layer flat-panel detector (DL-FPD) technologies have been actively studied as promising dual-energy solutions for FPD-based cone-beam computed tomography (CBCT).
Zhou, Hao +3 more
core
An intrinsic photoactive star‐shaped zinc phtalocyanine‐poly(L‐glutamic acid) (ZnPc‐PGA) nanoplatform for multimodal glioblastoma (GBM) therapy and brain‐targeted elivery. A ZnPc‐PGA‐based multifunctional theranostic nanocarrier platform enables image‐guided, multimodal GBM therapy. ZnPc‐PGA nanocarriers support the integration of fluorescence imaging,
Amina Benaicha‐Fernández +14 more
wiley +1 more source

