Transmission-corrected x-ray fluorescence analysis of uranium and plutonium solutions using a dual transmission source [PDF]

open access: yes, 1987
The energy-dispersive x-ray fluorescence analysis (XRFA) technique has been implemented at several spent nuclear fuel reprocessing facilities for nondestructive measurements of uranium and/or plutonium concentrations in process streams and product ...
Ruhter, W. D., Camp, D. C.
core  

Dual Energy Radioscopy Applied to Waste Sorting

open access: yes, 2014
International audienceDual energy X-ray transmission technique is used since many years in the medical field for bone /soft tissues separation, as well as in luggage inspection for light/heavy materials distinction. Its application to waste sorting first
Duvauchelle, Philippe   +4 more
core   +2 more sources

$In$ $situ$ measurement of iron overload in liver tissue by dual-energy methods

open access: yes, 1996
The errors for determining liver iron content by dual-energy computed tomography (dual-energy CT) are calculated for the ideal case where only monochromatic x-ray beams are used. Because of the strong influence of spatial resolution on the radiation dose
Oelckers, S., Graeff, W.
core   +1 more source

Characterisation of silicon nanoparticles produced by mechanical attrition using scanning electron microscopy, energy dispersive X-ray spectroscopy and X-ray photoemission spectroscopy

open access: yes, 2012
Includes abstract.Includes bibliographical references.The establishment of printing technologies, using nanoparticle based inks, promises inexpensive manufacture of electronic devices.
Unuigbe, David Moweme
core  

Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR) [PDF]

open access: yes, 2011
The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development
Pincus, C   +5 more
core   +1 more source

The Utility of X-Ray Dual-Energy Transmission and Scatter Technologies for Illicit Material Detection

open access: yes, 1999
X-ray devices have demonstrated the ability to characterize a material at the molecular and atomic levels. This ability is particularly important for detecting plastic explosives, where object shape information cannot be used.
Lu, Qiang
core  

A preliminary study of the advantages of X-ray energy selection in CT imaging

open access: yes, 2007
It is well known that a monochromatic X-ray source with an energy optimized for the organ thickness to be imaged could result in a better image quality in transmission radiology.
Bisogni, M. G.   +24 more
core   +2 more sources

Evaluation of a EMCCD detector for emission-transmission computed tomography [PDF]

open access: yes, 2006
A prototype electron multiplying charged coupled device (EMCCD) based gamma camera is evaluated for emission-transmission computed tomography. The detector has an 8.2 x 8.2 mm(2) active sensor area with a 512 X 512 pixel array, and can be operated with a
Shestakova, I   +5 more
core  

Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging

open access: yes, 2010
We investigate the feasibility of dual-energy method for image contrast enhancement in small animal studies using a low kV X-ray radiographic system.
Sidky, E.Y.   +3 more
core  

Dual-hop transmissions with fixed-gain relays over Generalized-Gamma fading channels

open access: yes, 2010
In this paper, a study on the end-to-end performance of dual-hop wireless communication systems equipped with fixed-gain relays and operating over Generalized-Gamma (GG) fading channels is presented.
Mansour, Akil   +2 more