Results 11 to 20 of about 51,223 (249)

PMU and DVR based Power System Monitoring, Controlling and Voltage sag Compensation [PDF]

open access: yesITM Web of Conferences, 2020
The power system network is becoming dense and much more complex. Dynamic and continuous monitoring of the power system network is required to avoid power outages. Phasor Measurement Unit (PMU) is one such device that provides state estimation parameters
Chalwadi Abhishek, M Kiruthika, S Bindu
doaj   +1 more source

Hybrid control mechanism-based DVR for mitigation of voltage sag and swell in solar PV-based IEEE 33 bus system

open access: yesInternational Journal of Power Electronics and Drive Systems (IJPEDS), 2023
The power quality issues are raised due to sag/swell, which affects the overall performance of the grid-connected system. This study introduces the hybrid control mechanism based on a dynamic voltage restorer (DVR) to mitigate the sag and swell issues in
Sowmyashree Narayana Setty   +2 more
semanticscholar   +1 more source

Voltage Quality Enhancement of Low-Voltage Smart Distribution System Using Robust and Optimized DVR Controllers: Application of the Harris Hawks Algorithm

open access: yesInternational Transactions on Electrical Energy Systems, 2022
The voltage quality (VQ) index has become a significant measure of recent power system stability. The integration of photovoltaic (PV) systems plus smart home loads (SHLs) at low voltage levels (LVLs) has resulted in various issues such as harmonics rise
Mohamed Metwally Mahmoud   +7 more
semanticscholar   +1 more source

Fault Current Limiter Dynamic Voltage Restorer (FCL-DVR) With Reduced Number of Components [PDF]

open access: yesIEEE Journal of Emerging and Selected Topics in Industrial Electronics, 2021
In this article, a new dual-function fault-current limiter-dynamic voltage restorer (FCL-DVR) topology is proposed. The proposed structure, in addition to performing routine FCL tasks, can be used to improve the voltage quality of point of common ...
Pedram Ghavidel   +4 more
semanticscholar   +1 more source

Three Phase Four Switch Inverter Based DVR for Power Quality Improvement With Optimized CSA Approach

open access: yesIEEE Access, 2022
Industries driven by electric power require controlled and improved power quality for the optimal exploitation of resources. However, certain crucial issues greatly influence power quality, causing monetary losses to both the utility and customers ...
Sanepalle Gopal   +4 more
semanticscholar   +1 more source

Improved instantaneous reactive power (PQ) Theory Based control of DVR for Compensating Extreme sag and swell

open access: yesIEEE Access, 2022
In today’s power system, power quality is a critical topic having several impacts on customers and utilities. In the current electric power system, the integration of renewable energy sources, smart grid technologies, and significant usage of power ...
S. Al-Gahtani   +3 more
semanticscholar   +1 more source

Performance evaluation of hybrid multilevel inverter with a high-frequency switching technique

open access: yesJournal of Engineering and Applied Science, 2023
This proposed work deals with the implementation of a single-phase topology with using hybrid for multilevel inverters. It is observed that the proposed structure improves the performance of the hybrid multilevel inverter with high-frequency switches for
B. Pragathi   +3 more
doaj   +1 more source

Protection of Sensitive Loads in Distribution Systems Using a BSFCL-DVR System

open access: yesSensors, 2021
In this paper, an incorporated bridge-type superconducting fault current limiter (BSFCL) and Dynamic Voltage Restorer (DVR) is presented to improve the voltage quality and limiting fault current problems in distribution systems. In order to achieve these
Mehdi Firouzi   +4 more
doaj   +1 more source

Analisis Tegangan Sag Pada Sistem Distribusi GI Sengkaling Penyulang Pujon Menggunakan Kompensasi DVR

open access: yesJurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems), 2020
Makalah ini mendiskusikan tentang analisis tegangan sag dalam sistem distribusi. Tegangan sag disebabkan gangguan hubung singkat 1 fasa ke tanah. Tegangan sag memberikan dampak kerusakan pada beban Pujon.
Arief Trisno Eko S   +2 more
doaj   +1 more source

Attenuation of Zero Sequence Voltage Using a Conventional Three-Wire Dynamic Voltage Restorer

open access: yesEnergies, 2021
Voltage sags/swells and harmonics are recurring problems in electric energy distribution systems. In order to solve these issues, several dynamic voltage restorer (DVR) topologies, such as the conventional three-wire DVR, have been proposed in the ...
Rafael Neto   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy