A Clinical Comparison of Dynamic Contour Tonometry Versus Goldmann Applanation Tonometry
Ophthalmic Surgery, Lasers and Imaging Retina, 2010Background and Objective: To compare the intraocular pressures (IOP) obtained with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) and to determine the dependency of both devices on corneal structure.
Baykara, MEHMET +3 more
openaire +3 more sources
Rebound, Applanation, and Dynamic Contour Tonometry in Pathologic Corneas
Cornea, 2013To compare the practicability of using an Icare rebound tonometer (RT) versus a Goldmann applanation tonometer (GAT) or a Pascal dynamic contour tonometer (DCT) for measuring intraocular pressure (IOP) in patients with corneal abnormalities and, furthermore, to study the influence of central corneal thickness, corneal diameter, corneal radius, and ...
A. Rosentreter +5 more
semanticscholar +3 more sources
Journal of Glaucoma, 2006
The dynamic contour tonometer (DCT, Pascal tonometer, Swiss Microtechnology AG, Port, Switzerland) was recently introduced as a new method of intraocular pressure measurement, supposedly independent of corneal properties. In this study we analyzed the agreement and correlation of dynamic contour tonometry and Goldmann applanation tonometry (GAT) and ...
Evelin, Schneider, Franz, Grehn
openaire +2 more sources
The dynamic contour tonometer (DCT, Pascal tonometer, Swiss Microtechnology AG, Port, Switzerland) was recently introduced as a new method of intraocular pressure measurement, supposedly independent of corneal properties. In this study we analyzed the agreement and correlation of dynamic contour tonometry and Goldmann applanation tonometry (GAT) and ...
Evelin, Schneider, Franz, Grehn
openaire +2 more sources
Dynamic Contour Tonometry in Keratoconus and Postkeratoplasty Eyes
Cornea, 2008To compare the performance of dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in measuring intraocular pressure in eyes with irregular corneas.GAT and DCT measures were taken in 30 keratoconus and 29 postkeratoplasty eyes of 35 patients after pachymetry and corneal topography.
Alexander, Meyenberg +3 more
openaire +2 more sources
Clinical & Experimental Ophthalmology, 2010
AbstractPurpose: To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) in eyes with pseudoexfoliation syndrome (PEX).Methods: Thirty‐eight patients (38 eyes) with PEX in both eyes (pseudoexfoliative group, PG) as well as 19 patients (19 eyes) without PEX in either eye (control group, CG), were ...
Emilia, Grammenandi +3 more
openaire +2 more sources
AbstractPurpose: To evaluate differences between Goldmann Applanation Tonometry (GAT) and Dynamic Controur Tonometry (DCT) in eyes with pseudoexfoliation syndrome (PEX).Methods: Thirty‐eight patients (38 eyes) with PEX in both eyes (pseudoexfoliative group, PG) as well as 19 patients (19 eyes) without PEX in either eye (control group, CG), were ...
Emilia, Grammenandi +3 more
openaire +2 more sources
Canadian Journal of Ophthalmology, 2010
To evaluate dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements in eyes that underwent penetrating keratoplasty PKP). Prospective, cross-sectional, observational study.Thirty-one eyes of 28 patients were examined after PKP.All eyes had undergone PKP with interrupted sutures.
Artemios, Kandarakis +5 more
openaire +2 more sources
To evaluate dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) intraocular pressure (IOP) measurements in eyes that underwent penetrating keratoplasty PKP). Prospective, cross-sectional, observational study.Thirty-one eyes of 28 patients were examined after PKP.All eyes had undergone PKP with interrupted sutures.
Artemios, Kandarakis +5 more
openaire +2 more sources
Dynamic Contour Tonometry for Post-LASIK Intraocular Pressure Measurements
Klinische Monatsblätter für Augenheilkunde, 2004Standard applanation tonometers are subject to systematic errors when applied to corneas with non-standard properties. Dynamic contour tonometry has been proposed as an alternative method for obtaining correct IOP data from such corneas. We have examined its applicability for patients who have undergone LASIK surgery.20 healthy individuals scheduled ...
I, Duba, A C, Wirthlin
openaire +2 more sources
Ophthalmology, 2007
To evaluate the relationship between intraocular pressure (IOP) measurements obtained by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in African Americans and to assess whether these measures were influenced by ocular parameters including corneal thickness, corneal curvature, and axial length.Observational clinical study.The
Felipe A, Medeiros +2 more
openaire +2 more sources
To evaluate the relationship between intraocular pressure (IOP) measurements obtained by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in African Americans and to assess whether these measures were influenced by ocular parameters including corneal thickness, corneal curvature, and axial length.Observational clinical study.The
Felipe A, Medeiros +2 more
openaire +2 more sources
[Evaluation of dynamic contour tonometry in keratoconus].
Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2009The gold standard for measuring intraocular pressure (IOP) until now has been Goldmann applanation tonometry (GAT), which depends on the central corneal thickness (CCT) and curvature. In patients with keratoconus who have an abnormal corneal geometry and thickness, measurement of pressure with GAT is often difficult and not very reproducible.
N, Schädle +3 more
openaire +1 more source
Influence of LASEK on Schiøtz, Goldmann and dynamic contour Tonometry
Graefe's Archive for Clinical and Experimental Ophthalmology, 2017M. Sales-Sanz +3 more
semanticscholar +1 more source