Results 141 to 150 of about 3,555,475 (231)

Multi‐Parametric Fluorescence Spectroscopy for the Detection and Characterization of Plant‐Derived Protein Residues on 316L Stainless Steel

open access: yesAdvanced Materials Interfaces, EarlyView.
UV–vis fluorescence spectroscopy enables sensitive monitoring of plant protein adsorption on AISI 316L stainless steel under food‐processing‐relevant conditions. Spectral deconvolution reveals adsorption‐induced changes associated with protein–surface interactions and conformational alterations, demonstrating the potential of the technique for ...
Alexander Khort   +6 more
wiley   +1 more source

The Numerical and Analytical Analysis of the Diaphragm Deflection Actuated by the Shear Mode Piezoelectric Actuator in Micropump

open access: yes, 2012
[[abstract]]A shear mode piezoelectric actuator is first applied to deflect the rectangular diaphragm of the micropump designed with the rectangular pressure chamber and the diffuser as the dynamic passive valve.
Chen, S. C. ; Cheng, C. H. ; Lin, Yi- Cheng
core  

In‐House Manufacturing of 3D ECM Culture Chips via Vacuum Thermoforming for Enhanced Imaging Applications

open access: yesAdvanced Materials Technologies, EarlyView.
Desktop vacuum thermoforming enables rapid, low‐cost fabrication of 96‐channel polystyrene culture chips with very thin imaging interfaces. The resulting platform supports cell lines, primary cells, and patient‐derived organoids, and enables high‐resolution confocal microscopy and single‐cell visualization, providing an accessible approach for advanced
Aleksandra Fomina   +5 more
wiley   +1 more source

Characterized Ecoflex Polydimethylsiloxane (PDMS) Hybrids for Advanced Flexible Devices

open access: yesAdvanced Materials Technologies, EarlyView.
Ecoflex–PDMS hybrids are systematically characterized to identify an optimal composition that balances stretchability, optical transparency, and plasma bonding, enabling multifunctional applications in stretchable microfluidics, flexible sensing, and soft robotics.
Xiaoyue Kang   +10 more
wiley   +1 more source

Liquid Crystal Elastomer Actuator Matrix for Large Area Applications

open access: yesAdvanced Materials Technologies, EarlyView.
A scalable approach is used to manufacture a digitally‐controllable, 2D 5 × 5 actuator matrix. The elements of the matrix are produced by direct ink writing of a liquid crystal elastomer ‘artificial muscle’ on large‐area flexible thin‐film heaters. In optimizing the low‐power actuators, multiple heater designs and substrate materials are investigated ...
Giulia Spallanzani   +5 more
wiley   +1 more source

Biodegradable and Edible Milli‐Fluidic Logic Circuits

open access: yesAdvanced Materials Technologies, EarlyView.
Fully biodegradable and edible fluidic circuits are developed using gelatin‐based valves that operate at low pressure. Logic gates, a one‐bit memory, and a ring oscillator are demonstrated, showing that biodegradable materials can perform computation and control.
Shuhang Zhang   +3 more
wiley   +1 more source

Dynamic Deflection Gage for Long Span

open access: yesJournal of Zosen Kiokai, 1960
openaire   +2 more sources

Liquid Metal Resistive Sensing Architectures for Measuring Diaphragm Strain Responses on Obstructed Surfaces

open access: yesAdvanced Materials Technologies, EarlyView.
A liquid metal‐based strain‐sensing architecture to measure the deformation of a circular diaphragm against obstructed surfaces is formulated using finite element modeling and confocal imaging to establish the mechanical framework and is utilized to control diaphragm‐induced confinement on a bead array, as validated by biomolecular loading level ...
Abdullah‐Bin Siddique   +4 more
wiley   +1 more source

Programming Actuation in 3D‐Printed Micro‐Architectures via Interfacial Adhesion Control

open access: yesAdvanced Materials Technologies, EarlyView.
A two‐phase meniscus‐guided 3D printing method directly fabricates microscale poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) and poly(vinyl alcohol) (PVA) bilayers with in situ programmable interfaces. Modulating the meniscus stretching speed switches the interface between separated and bonded states, which controls the mechanical ...
Xiao Huan   +13 more
wiley   +1 more source

Bioinspired Adaptive Artificial Cilia With Tunable Sensitivity and Dynamic Range for Airflow Monitoring in the Central Airway

open access: yesAdvanced Materials Technologies, EarlyView.
A magnetically reconfigurable airflow sensor integrated with an airway stent enables tunable sensitivity and dynamic sensing range. Airflow‐induced cantilever deformation generates resistance changes, while an external magnetic field modulates sensor stiffness, enhancing sensitivity at low airflow velocities and extending the sensing range at higher ...
Darren Wang   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy