A Simple Technique for the Positioning of a Patient with an above Knee Amputation for an Ipsilateral Extracapsular Hip Fracture Fixation

open access: yesCase Reports in Orthopedics, 2013
The positioning of the patient on the fracture table is critical to the successful reduction and operative fixation of hip fractures which are fixed using the dynamic hip screw system (DHS).
N. Davarinos, P. Ellanti, G. McCoy
doaj   +1 more source

Errores de osteosíntesis en fracturas laterales de cadera tratadas con placa/tornillo deslizante [Osteosynthesis pitfalls in lateral hip fractures treated with plate / sliding screw system].

open access: yesRevista de la Asociación Argentina de Ortopedia y Traumatología, 2019
Introducción: El uso de los sistemas placa/tornillo deslizante para fracturas intertrocantéricas ha demostrado ser un método de fijación eficaz, pero no está exento de fallas.
César Ángel Pesciallo   +3 more
doaj   +1 more source

The effect of full‐limb flexion tests on static and dynamic muscle activity and locomotion asymmetry in owner‐sound horses

open access: yesEquine Veterinary Journal, EarlyView.
Abstract Background Flexion tests are commonly used in equine locomotion examinations to identify underlying locomotor issues, yet their neuromuscular effects remain poorly understood. Response variability raises concerns about their clinical value in lameness assessments and pre‐purchase evaluations.
Marijke Jonkhart   +4 more
wiley   +1 more source

Finite element analysis of implant selection and screw positioning in proximal femoral basicervical fractures

open access: yesScientific Reports
To determine the optimal implant for proximal femoral basicervical fractures by comparing the biomechanical properties of the Dynamic Hip Screw (DHS), Proximal Femoral Nail Anti-Rotation (PFNA), and InterTAN using finite element analysis (FEA).
Tianhao Yang   +4 more
doaj   +1 more source

Comparison of Proximal Femoral Nail Antirotation and Dynamic Hip Screw Internal Fixation on Serum Markers in Elderly Patients with Intertrochanteric Fractures.

open access: yesJournal of the College of Physicians and Surgeons--Pakistan : JCPSP, 2019
OBJECTIVE To compare effect of proximal femoral nail antirotation (PFNA) and dynamic hip screw (DHS) internal fixation on serum inflammatory mediators (CRP, IL-1, IL-6 and TNF-α), myocardial injury markers (cTnT, CK-MB), and Myo-heart failure marker (BNP)
Bin Wang, Qingbai Liu, Yu Liu, Rui Jiang
semanticscholar   +1 more source

Racially Hegemonic Articulations: Class as Race in Constructions of Dominance in an Undergraduate Architecture Studio

open access: yesJournal of Sociolinguistics, EarlyView.
ABSTRACT This article responds to recent debates in this journal surrounding raciolinguistics and potential pitfalls of siloing of race and reproducing essentialism in the scholarship of language and race. Using Stuart Hall's theory of articulation, it provides an anti‐essentialist linguistic ethnographic analysis of identity construction in a UK ...
Steve Dixon‐Smith
wiley   +1 more source

Minimally invasive osteosynthesis using a dynamic compression angle‐stable interlocking nail in feline transverse femoral fractures: an ex vivo study

open access: yesJournal of Small Animal Practice, EarlyView.
Objective To evaluate the effectiveness of interfragmentary compression in feline femoral transverse fractures treated with a dynamic compression angle‐stable interlocking nail implanted via minimally invasive nail osteosynthesis. Methods Thirty femurs from 15 feline cadavers were allocated into three groups according to fracture location (n = 10 per ...
M. Nobile   +6 more
wiley   +1 more source

Treatment Trade‐Offs and Choices for Femoral Fractures: A Systematic Review and Meta‐Analysis

open access: yesOrthopaedic Surgery, Volume 17, Issue 5, Page 1298-1313, May 2025.
This review examines the trade‐offs between surgical intervention and traction therapy for adult and elderly patients with femoral fractures and surgical contraindications, particularly in resource‐limited settings. While intramedullary nailing may offer better clinical outcomes, traction therapy is often preferred due to limited surgical resources ...
Jiarui Li   +11 more
wiley   +1 more source

Interprosthetic Fracture of Distal Femur around Total Knee Replacement with Pre-Existing Dynamic Condylar Screw

open access: yesJournal of Orthopaedics, Trauma and Rehabilitation, 2016
Treatment of interprosthetic fracture of distal femur around total knee replacement is difficult. Preexisting hip implants further increase the technical challenges.
Lau Chi Kin   +2 more
doaj   +1 more source

Locking plates increase the strength of dynamic hip screws

open access: yesInjury, 2008
Failure of a dynamic hip screw (DHS) fixation leads to decreased mobility of the patient and frequently to a decrease in general health. The most common mode of failure of a DHS is cut out of the lag screw from the femoral head. The second most common mode of failure is lift-off of the plate from the femur. The aim of this laboratory-based experimental
Jewell, D   +3 more
openaire   +3 more sources