Results 71 to 80 of about 6,067 (195)
Locking plates increase the strength of dynamic hip screws
Failure of a dynamic hip screw (DHS) fixation leads to decreased mobility of the patient and frequently to a decrease in general health. The most common mode of failure of a DHS is cut out of the lag screw from the femoral head. The second most common mode of failure is lift-off of the plate from the femur. The aim of this laboratory-based experimental
Jewell, D +3 more
openaire +3 more sources
Treatment Trade‐Offs and Choices for Femoral Fractures: A Systematic Review and Meta‐Analysis
This review examines the trade‐offs between surgical intervention and traction therapy for adult and elderly patients with femoral fractures and surgical contraindications, particularly in resource‐limited settings. While intramedullary nailing may offer better clinical outcomes, traction therapy is often preferred due to limited surgical resources ...
Jiarui Li +11 more
wiley +1 more source
A 64-year-old woman with a spontaneous fused hip sustained a left femoral neck fracture. It was revealed that her left hip joint had a long-standing spontaneous hip fusion due to end-stage osteoarthritis.
Saori Niitsu +4 more
doaj +1 more source
This largest Asian case series confirms that posterior spinal fusion for SMA scoliosis is safe and effective despite severe deformity and markedly impaired pulmonary function. Meticulous multidisciplinary care, including advanced airway planning, hemodynamic support, blood management, and proactive electrolyte correction, is critical to optimizing ...
Ai Hu +7 more
wiley +1 more source
To determine the optimal implant for proximal femoral basicervical fractures by comparing the biomechanical properties of the Dynamic Hip Screw (DHS), Proximal Femoral Nail Anti-Rotation (PFNA), and InterTAN using finite element analysis (FEA).
Tianhao Yang +4 more
doaj +1 more source
30-day morbidity and mortality after hip surgery – A single-centre study.
Objective: To evaluate the 30-day morbidity and mortality after hip surgery in a low-resource setting, and to identify the key risk factors. Method: The retrospective study was conducted in January 2023 at the Department of Orthopaedic Surgery, Aga Khan
Junaid Khan +5 more
doaj +1 more source
Introducción: El uso de los sistemas placa/tornillo deslizante para fracturas intertrocantéricas ha demostrado ser un método de fijación eficaz, pero no está exento de fallas.
César Ángel Pesciallo +3 more
doaj +1 more source
Autonomous Frameless Spine Registration and Robot‐Assisted Surgery
Workflow of a contactless, frame‐free, robot‐assisted vertebra registration system. Preoperative CT data establish vertebra {V} and mask {Mpre} coordinate systems. Their relationship is computed, and intraoperatively the robot recognizes the skin‐affixed mask, defining {Mintra}.
Amit Kumar +4 more
wiley +1 more source
Abstract Objectives Global population aging is leading to a greater retention of natural teeth into later life and an increasing prevalence of dental implant therapy. Although advanced age has traditionally been regarded as a risk factor for compromised outcomes, population level evidence remains lacking.
Dong Yang +3 more
wiley +1 more source
The positioning of the patient on the fracture table is critical to the successful reduction and operative fixation of hip fractures which are fixed using the dynamic hip screw system (DHS).
N. Davarinos, P. Ellanti, G. McCoy
doaj +1 more source

