Earthing effects on mitochondrial function: ATP production and ROS generation [PDF]

open access: yesFEBS Open Bio
Mitochondria are central to cellular energy production and the regulation of oxidative stress. Traditional methods for assessing mitochondrial ATP and reactive oxygen species (ROS) rely on metal probes, which unintentionally ground the system ...
Cecilia Giulivi, Richard Kotz
doaj   +2 more sources

Illnesses in technologically advanced societies due to lack of grounding (earthing). [PDF]

open access: yesBiomed J, 2023
The research on grounding or earthing summarized here is providing valuable clues about why chronic and autoimmune diseases are rampant, simple and reliable help for those with these health issues, and promising paths forward. During the period when this
Oschman JL.
europepmc   +2 more sources

Electromechanical Analysis of the Medium Voltage Earthing Switch due to Short-Time and Peak Withstand Current Test

open access: yesEnergies, 2019
The chosen electrical equipment, i.e., the earthing switch has its application in marine switchgear. In this paper, the reduction of dimensions is considered with the purpose of making it more energy efficient in terms of onboard application.
Maja Krčum   +2 more
doaj   +2 more sources

Investigation of different system earthing schemes for protection of low-voltage DC microgrids

open access: yesThe Journal of Engineering, 2019
DC microgrids are expected to play an important role in maximising the benefits of distributed energy resources in future low carbon smart power systems.
Ahmad Makkieh   +4 more
doaj   +2 more sources

Development and Performance Evaluation of Low-Cost 2WT-Operated Earthing-Up Machine for Sugarcane Cultivation in Bangladesh

open access: yesAgriEngineering, 2023
Like most crops, sugarcane needs to be kept upright until it is harvested. The lodging of sugarcane has significant negative effects on the cane yield and sugar content of sugarcane.
Md. Nafiul Ferdows   +6 more
doaj   +1 more source

Transient analysis of earthing electrodes considering soil ionization phenomenon under lightning impulse condition

open access: yesElectrical Engineering, 2023
This paper presents the transient behavior of an earthing system under the influence of lightning current injected in to it. Vertical rods and horizontal electrodes buried in homogeneous soil are considered in this analysis.
K. Sengar, Kandasamy Chandrasekaran
semanticscholar   +1 more source

COMPARISON OF EARTHING TECHNIQUES FOR SINGLE LINE TO GROUND FAULT IN 11 kV DISTRIBUTION SYSTEM USING SIMULINK [PDF]

open access: yesJournal of Engineering and Sustainable Development, 2019
In this paper, a new smart earthing method was proposed to reduce the current magnitude of single line to ground fault and thus reduce the damage caused by this fault. Traditional methods of earthing system were studied and compared with the proposed new
Ali Abdulabbas Abdullah   +2 more
doaj   +3 more sources

Monitoring, Detection and Locating of Transient Earth Fault Using Zero-Sequence Current and Cable Screen Earthing Current in Medium Voltage Cable and Mixed Feeders

open access: yesEnergies, 2022
This paper presents the final development of an expert system utilizing a measurement of cable screen earthing transient current. The developed system allows for identification and location of earth fault in underground cable and mixed lines (underground
Krzysztof Łowczowski, B. Olejnik
semanticscholar   +1 more source

Statistical Assessment of Electric Shock Hazard in MV Electrical Power Substations Supplied from Networks with Non-Effectively Earthed Neutral Point

open access: yesEnergies, 2022
This paper focuses on the evaluation of the electric shock hazard accompanying earth faults in a non-effectively earthed medium-voltage (MV) electrical power network. This hazard depends on the duration and value of the fault current.
Rafał Tarko   +3 more
doaj   +1 more source

STUDI EVALUASI DAN RENOVASI SISTEM PENTANAHAN DI SEKOLAH MENENGAH KEJURUAN (SMK) NEGERI 1 CIMAHI

open access: yesMadani: Jurnal Pengabdian kepada Masyarakat, 2021
This research is a follow-up to the findings of the inspection and grounding testing in PKM 2018 activities. The value obtained exceeds 5 ohms. This is not according to the standards based on the General Requirements for Electrical Installation (PUIL ...
Sunarto Sunarto   +5 more
doaj   +1 more source