Results 211 to 220 of about 2,011,630 (289)

Negative Chemotaxis of Urease‐Functionalized Polymeric Microcapsules

open access: yesSmall, EarlyView.
Urease‐functionalized PLGA microcapsules exhibit negative chemotaxis in urea gradients, migrating from high to low substrate concentrations. Increasing gradients enhance chemotaxis until a plateau, while increasing average substrate concentration in a fixed gradient reverses chemotactic behavior.
Amanda Hopkins   +2 more
wiley   +1 more source

Microfluidic Molecular Diagnostic Chips: Functional Modules, Integration Strategies, and Emerging Applications

open access: yesSmall Methods, EarlyView.
This comprehensive review delivers an engineering‐centric analysis of microfluidic molecular diagnostic chips, breaking them down into foundational modules from fluid manipulation to bio‐sensing. Beyond chip design, it evaluates sample‐to‐answer integration strategies and commercial readiness levels.
Donghoon Koo   +7 more
wiley   +1 more source

Sensitivity study on accuracy and relevant parameters in numerical modeling of internal tendon breaks

open access: yesStructural Concrete, EarlyView.
Abstract This study investigates the numerical modeling of internal tendon breaks in prestressed concrete structures and evaluates the key parameters affecting accuracy. A combined approach is followed, involving global sensitivity analysis via the Elementary Effects Method and subsequent model calibration using experimental data from distributed fiber‐
Aeneas Paul, David Sanio, Peter Mark
wiley   +1 more source

A method for determining the performance of formulas for calculating the crack width and spacing in reinforced concrete elements

open access: yesStructural Concrete, EarlyView.
Abstract Numerous studies have been conducted to determine the performance of formulas for calculating crack width and spacing in reinforced concrete structures. Generally, these studies pay limited attention to the application areas of those formulas and how to compare different representations of the crack width and spacing.
Anton van der Esch   +2 more
wiley   +1 more source

Behavior of manufactured sand and recycled coarse aggregate concrete‐filled steel tubular stub columns with circular section

open access: yesStructural Concrete, EarlyView.
Abstract Accelerated urbanization has intensified environmental concerns due to excessive natural resource consumption and construction waste generation. Circular concrete‐filled steel tube (CFST) columns incorporating manufactured sand recycled coarse aggregate (MS‐RCA) concrete have emerged as an innovative composite element offering notable ...
Minsheng Guan   +7 more
wiley   +1 more source

The influence of secondary reinforcement on a strut‐and‐tie model for the design of reinforced concrete corbels

open access: yesStructural Concrete, EarlyView.
Abstract In precast concrete structures, optimizing the design of corbels by considering the contributions of secondary reinforcement elements can significantly improve construction economy, especially when corbels are repeated multiple times. This paper proposes a strut‐and‐tie model for reinforced concrete corbels subjected to vertical and/or ...
Rejane Martins Fernandes Canha   +3 more
wiley   +1 more source

Deformation and strength of grouted sleeve connectors in pre‐fabricated concrete structures: Mechanisms and analytical modeling

open access: yesStructural Concrete, EarlyView.
Abstract Grouted sleeve connectors (GSCs) are widely used in precast/prefabricated concrete structures. To ensure force transfer, connectors are often overdesigned in length. This practice has an unintended consequence of reducing the plastic deformation capacity of the connection region and hence the displacement ductility of the precast structure as ...
Hongning Ye, Yong Lu
wiley   +1 more source

Identification of invisible damage in prestressed concrete bridges—A demonstrator case using coda wave interferometry

open access: yesStructural Concrete, EarlyView.
Abstract During their life cycle, prestressed concrete bridges are prone to wire breaks of their tendons due to fatigue or stress corrosion cracking. However, not all structures show visible cracking on the surface, which would provide timely warning of otherwise invisible damage. Brittle failure may occur.
Noah Sträter   +3 more
wiley   +1 more source

Structural behavior of small square steel tubes reinforced self‐compacting concrete columns under biaxial eccentric loads

open access: yesStructural Concrete, EarlyView.
Abstract In this study, the structural behavior of small square steel tube‐reinforced self‐compacting concrete (SSTR‐SCC) columns is investigated under symmetric and asymmetric biaxial eccentric loads. Twelve specimens were cast and tested under biaxial eccentric loads.
Muhammad Naveed   +2 more
wiley   +1 more source

Deflection‐based assessment of residual prestress in simply‐supported bridges accounting for creep variability

open access: yesStructural Concrete, EarlyView.
Abstract Several test methods have been proposed in the literature for measuring the level of residual prestress, most of them involving either semi‐ or fully destructive techniques for local measurements which could be highly sensitive to boundary conditions and execution details.
Giuseppe Zarrella   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy