Results 1 to 10 of about 423 (47)

Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging

open access: yesFrontiers in Neuroscience, 2022
ObjectivesTo compare the performances of single-shot echo-planar imaging (SS–EPI) and readout-segmented echo-planar imaging (RS–EPI) for diffusion tensor imaging (DTI) of the rat sciatic nerve.MethodsEight healthy adult male Sprague-Dawley rats were ...
Yueyao Chen   +9 more
doaj   +1 more source

Comparison of spin-echo echo-planar imaging magnetic resonance elastography with gradient-recalled echo magnetic resonance elastography and their correlation with transient elastography

open access: yesDiagnostic and Interventional Radiology, 2022
PURPOSEThis study aimed to assess the agreement between liver stiffness (LS) values obtained by the gradient-recalled echo (GRE) magnetic resonance elastography (MRE) and spin-echo echo-planar imaging (SE-EPI) MRE with those of transient elastography (TE)
Jin Woo Yoon   +6 more
doaj   +1 more source

Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging

open access: yesNeuroImage, 2021
Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition.
Zijing Dong   +6 more
doaj   +1 more source

Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging. [PDF]

open access: yesPLoS ONE, 2015
Here we investigate the utility of a dual-echo Echo-Planar Imaging (DE-EPI) Diffusion Weighted Imaging (DWI) approach to improve lesion conspicuity in pediatric imaging. This method delivers two 'echo images' for one diffusion-preparation period. We also
Kristen W Yeom   +6 more
doaj   +1 more source

A high temporal/spatial resolution neuro-architecture study of rodent brain by wideband echo planar imaging

open access: yesScientific Reports, 2021
Latest simultaneous multi-slice (SMS) methods greatly benefit MR efficiency for recent studies using parallel imaging technique. However, these methods are limited by the requirement of array coils. The proposed Coherent Wideband method, which employs an
Po-Wei Cheng   +2 more
doaj   +1 more source

High-Resolution SAR Imaging with Azimuth Missing Data Based on Sub-Echo Segmentation and Reconstruction

open access: yesRemote Sensing, 2023
Due to the substantial electromagnetic interference, radar interruptions, and other factors, the SAR system may fail to receive valid data in some azimuth areas. This phenomenon is known as Azimuth Missing Data (AMD).
Nan Jiang   +5 more
doaj   +1 more source

Calgary Preschool magnetic resonance imaging (MRI) dataset

open access: yesData in Brief, 2020
The Calgary Preschool MRI Dataset in the Developmental Neuroimaging Lab at the University of Calgary uses magnetic resonance imaging (MRI) techniques to study brain structure and function in early childhood [1–3].
Jess E. Reynolds   +4 more
doaj   +1 more source

Comparison of Diagnostic Performance and Image Quality between Topup-Corrected and Standard Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Cholesteatoma Diagnostics

open access: yesDiagnostics, 2023
This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics.
Marco Wiesmueller   +9 more
doaj   +1 more source

fMRI protocol optimization for simultaneously studying small subcortical and cortical areas at 7 ​T

open access: yesNeuroImage, 2020
Most fundamental cognitive processes rely on brain networks that include both cortical and subcortical structures. Studying such networks using functional magnetic resonance imaging (fMRI) requires a data acquisition protocol that provides blood ...
Steven Miletić   +5 more
doaj   +1 more source

Assessment of Rat Sciatic Nerve Using Diffusion-Tensor Imaging With Readout-Segmented Echo Planar Imaging

open access: yesFrontiers in Neuroscience, 2022
ObjectivesThis study aimed to compare readout-segmented-3, readout-segmented-5, and readout-segmented-7 echo-planar imaging (RS3-EPI, RS5-EPI, and RS7-EPI) of DTI in the assessment of rat sciatic nerve at 3T MR.MethodsEight male adult healthy Sprague ...
Yueyao Chen   +9 more
doaj   +1 more source

Home - About - Disclaimer - Privacy