Results 81 to 90 of about 108,295 (312)
ABSTRACT Background The EMPIRE I study assessed the early (30 days) safety and efficacy of a new fully repositionable delivery system (IMPERIA) for the commercially available ALLEGRA transcatheter aortic valve in patients with either severe native aortic stenosis or a degenerated surgical bioprosthesis.
José Antonio Baz +15 more
wiley +1 more source
In this study we compared the real time three dimensional echocardiogram data in evaluation of patent ductus arteriosus with the gold standard angiography.MethodsThis study included 25 patients with PDA referred to Tanta University Hospital for elective ...
Elsetiha, Mohamed +3 more
core +1 more source
ABSTRACT Background Deflectable delivery systems have been introduced to enhance coaxial alignment and procedural efficacy during left atrial appendage occlusion (LAAO), yet randomized comparisons with conventional fixed‐curve systems are lacking. Aims The GUIDE‐LAAO trial evaluated whether the TruSteer deflectable delivery system is non‐inferior to ...
Philippe Taieb +3 more
wiley +1 more source
Abstract Background Gene transcription is crucial for embryo and postnatal development and is regulated by the Mediator complex. Mediator is comprised of four submodules, including the kinase submodule (CKM). The CKM consists of MED13, MED12, CDK8, and CCNC.
Anna K. Leinheiser +5 more
wiley +1 more source
ECHOCARDIOGRAM VIDEOS: SUMMARIZATION, TEMPORAL SEGMENTATION AND BROWSING
In this paper, we present a system for the temporal segmentation, summarization, and browsing of the Echocardiogram videos. Echocardiogram videos are video sequences produced by the ultrasound scanning of the heart, and are one of the main modalities of ...
Shih-fu Chang, Shahram Ebadollahi
core
Abstract Wild‐type transthyretin amyloid cardiomyopathy (ATTRwt‐CM) is a progressive and infiltrative cardiac disorder that may cause fatal consequences if left untreated. The estimated survival time from diagnosis is approximately 3–6 years. Because of the non‐specificity of initial symptom manifestation and insufficient awareness among treating ...
Yasuhiro Izumiya +9 more
wiley +1 more source
Abstract Background Unexplained exertional dyspnoea without significant elevation of natriuretic peptides is common. One of the causes might be early heart failure with preserved ejection fraction (HFpEF). Aims This study aimed to characterize patients with exertional dyspnoea and normal/near‐to‐normal N‐terminal pro‐brain natriuretic peptide (NT ...
Emmanuelle Berthelot +8 more
wiley +1 more source
Objective: To summarize echocardiographic characteristics of the anatomy and hemodynamic and clinical outcomes in fetuses with isolated pulmonary stenosis (PS) or pulmonary atresia with intact ventricular septum (PA/IVS).
Chengcheng Pang +5 more
doaj +1 more source
Abstract Aims Heart failure with preserved ejection fraction (HFpEF) continues to be an increasingly common health problem associated with a high mortality rate. Elevated levels of Growth differentiation factor‐15 (GDF15) and N‐terminal pro‐brain natriuretic peptide (NT‐proBNP) are reportedly associated with poor clinical outcomes in a broad range of ...
Yoichiro Otaki +11 more
wiley +1 more source
The synergy of 3D SIFT and sparse codes for classification of viewpoints from echocardiogram videos
Echocardiography plays an important part in diagnostic aid in cardiology. During an echocardiogram exam images or image sequences are usually taken from different locations with various directions in order to comprehend a comprehensive view of the ...
Wang, C., Qian, Y., Wang, L., Gao, X.
core +1 more source

