Results 81 to 90 of about 114,235 (302)

Severe Headbanging Responsive to Levodopa in a Child With FOXP1 Syndrome

open access: yesAmerican Journal of Medical Genetics Part A, EarlyView.
ABSTRACT We report a 9‐year‐old female with FOXP1 syndrome due to a de novo in‐frame deletion in the FOXP1 gene. The child has a severe neurodevelopmental disorder including global developmental delay and autism spectrum disorder. At age 2, she developed severe headbanging, which was progressive and did not respond to multidisciplinary, behavioral ...
Pamela Veale   +2 more
wiley   +1 more source

Simultaneous Echocardiogram and N-Terminal-Probrain Natriuretic Peptide Measurement in Neonates

open access: yes, 2022
Natriuretic atrial peptides are secreted by the heart in response to the distension of the cardiac chambers, and the N-terminal-probrain natriuretic peptide (NT-proBNP) is used frequently by clinician as an indirect measure of cardiac distension.
Turnbough L, McKenna A, Manzar S
core   +1 more source

A Large Retrospective Study to Evaluate Utility of Zephyr Covered Stent in Transcatheter Closure of Sinus Venosus Defects

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Transcatheter closure (TCC) of sinus venosus defects (SVD) using balloon‐expandable covered stents is an emerging alternative to surgery. ZephyrCS (Sahajanand Laser Technologies, Gandhinagar, India) is available in long lengths to suit SVD closure.
Pramod Sagar   +3 more
wiley   +1 more source

A comprehensive framework for echocardiogram video analysis

open access: yes, 2007
The echocardiography examination of the heart provides a proficient assessment of the cardiac functional performance. The scanning of the heart is either recorded in an archive of analog videotapes or output in digital DICOM format that requires ...
Madbouly, Abeer
core   +3 more sources

The Incidence, Severity and Clinical Consequence of Left Pulmonary Artery Stenosis After PDA Device Closure in Premature Infants Less Than 2 Kilograms

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Transcatheter patent ductus arteriosus (PDA) device closure is an effective treatment option for premature infants with hemodynamically significant PDA. Left pulmonary artery (LPA) stenosis has been reported as a complication, however there is limited data on risk factors, clinical significance, and long‐term outcomes.
Bryan Mosher   +7 more
wiley   +1 more source

Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili   +2 more
wiley   +1 more source

Comparative study between real time three dimensional echocardiogram and angiography in evaluation of patent ductus arteriosus, single center experience [PDF]

open access: yes, 2014
In this study we compared the real time three dimensional echocardiogram data in evaluation of patent ductus arteriosus with the gold standard angiography.MethodsThis study included 25 patients with PDA referred to Tanta University Hospital for elective ...
Elsetiha, Mohamed   +3 more
core   +1 more source

Percutaneous Left Atrial Appendage Closure Using a PFO Occluder After an Incomplete Surgical Ligation

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT The case regards a 73‐year‐old male who was referred for consideration of percutaneous left atrial appendage closure. His left atrial appendage was ligated during prior mitral valve surgery, but was noted to be patent on a recent transesophageal echocardiography. An Amulet device was selected based on CT planning.
Zach Rozenbaum, Eric Gnall
wiley   +1 more source

Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton   +3 more
wiley   +1 more source

Echocardiogram dataset for survival analysis

open access: yes
Dataset Documentation: Extended UCI Echocardiogram Dataset 1. Overview The Extended UCI Echocardiogram Dataset is a synthetic dataset based on the original UCI Echocardiogram dataset.
sufian, abu
core   +1 more source

Home - About - Disclaimer - Privacy