Results 151 to 160 of about 327,544 (281)

Comparative multimodal calibration of patient‐specific atrial fibrillation models: Impact of imaging and electrophysiology data on arrhythmogenic substrate identification

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Comparative multimodal calibration of patient‐specific left atrial (LA) models to identify arrhythmogenic substrates in atrial fibrillation (AF). A, LA models shown in posterior and anterior views, calibrated separately using: late gadolinium enhancement magnetic resonance imaging (LGE‐MRI) image intensity ratio (IIR; blue–red ...
Mahmoud Ehnesh   +14 more
wiley   +1 more source

Comparison between lower-cost and conventional eddy covariance setups for CO2 and evapotranspiration measurements above monocropping and agroforestry systems

open access: yes
Novel, lower-cost setups of eddy covariance systems may offer a potential solution to the spatial replication problem of single flux towers. Prior to their widespread application, it is essential to conduct comprehensive testing against conventional eddy
Ramshorst, Justus G. V. van   +6 more
core   +1 more source

Localized Quadratic RF Encoded Spin‐Echo With Spiral‐PRIME Reconstruction: A Practical Alternative to 3D FSE for High‐Resolution Volumetric Brain MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 6, Page 2615-2628, December 2026.
ABSTRACT Purpose To extend localized quadratic (LQ) RF encoded spin‐echo imaging with acquisition and reconstruction strategies that improve efficiency and artifact robustness, positioning it as a practical alternative to 3D FSE for high‐resolution volumetric brain MRI.
Guruprasad Krishnamoorthy   +2 more
wiley   +1 more source

Human In Vivo Validation of Frequency‐Dependent QTI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 6, Page 2642-2659, December 2026.
ABSTRACT Purpose The aim of this work is to investigate if q‐space trajectory imaging (QTI) waveforms can be designed to probe QTI metrics at a single centroid frequency under realistic experimental conditions for in vivo human brain imaging. Methods Realistic diffusion encoding waveforms based on double‐rotation gradient waveform and magic‐angle ...
Svenja Niesen   +3 more
wiley   +1 more source

Improving Fetal Single‐Voxel Magnetic Resonance Spectroscopy With Spectral Registration

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 6, Page 2578-2587, December 2026.
ABSTRACT Purpose To evaluate whether spectral registration improves spectral quality and quantification reliability in in vivo single‐voxel fetal brain MRS: Methods Fourteen fetal PRESS datasets were acquired at 3 T at TE = 35 ms and TE = 135 ms. Raw data were processed with eddy‐current phase correction, coil combination, spectral registration, and ...
Andres Saucedo   +2 more
wiley   +1 more source

Spatial and temporal scales in plant phenotyping for crop water stress assessment: A review

open access: yesThe Plant Phenome Journal, Volume 9, Issue 1, December 2026.
Abstract Water stress is a major limiting factor for crop productivity worldwide, and its impacts are intensifying due to climate variability and increasing water scarcity. This review focuses on the spatial and temporal scales in plant phenotyping as a critical approach to improving crop water‐stress assessment and supporting precision water ...
Daniel Kingsley Cudjoe   +3 more
wiley   +1 more source

A widely-used eddy covariance gap-filling method creates systematic bias in carbon balance estimates. [PDF]

open access: yesSci Rep, 2023
Vekuri H   +8 more
europepmc   +1 more source

Group‐Patch Joint Compression: Compressing Dynamic B0 and Static RF Spatial Modulations Across k‐Space Subregion Groups for Highly Accelerated MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 5, Page 2106-2126, November 2026.
ABSTRACT Purpose To accelerate MRI further, rapid B0 field modulations can be applied during oversampled readout to capture additional physical information, as in Wave‐CAIPI/FRONSAC/local B0 coils modulation techniques. These methods, however, turn the Fourier readout into a non‐Fourier‐encoded dimension that cannot be reconstructed by FFT, posing ...
Rui Tian, Klaus Scheffler
wiley   +1 more source

Home - About - Disclaimer - Privacy