Abstract Background Radiobiological data suggests variations in relative biological effectiveness (RBE) between clinically used photon‐based sources. A microdosimetric formalism using Monte Carlo (MC) methods can mechanistically describe the photon RBE.
Mirta Dumančić +6 more
wiley +1 more source
Comparative dosimetry of GammaMed Plus high-dose rate 192 Ir brachytherapy source
The comparative dosimetry of GammaMed (GM) Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc
Patel N, Majumdar B, Vijayan V
doaj
Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed.
Hadad K +3 more
doaj
Determination of a beam quality conversion factor from 60Co to 192Ir
Radiation dosimetry is an integral part of the radiation therapy process. The ultimate goal of radiation dosimetry is to determine the dose delivered to the tumor and to the normal tissues in a patient undergoing radiotherapy. The importance of HDR 192Ir
Luciana Tourinho Campos +2 more
doaj +1 more source
Application of a Monte Carlo linac model in routine verifications of dose calculations
The analysis of some parameters of interest in radiotherapy Medical Physics based on an experimentally validated Monte Carlo model of an Elekta Precise lineal accelerator was performed for 6 and 15 MV photon beams.
Haydee M. Linares Rosales +3 more
doaj
Purpose: The purpose of the study was to estimate the backscatter electron dose in internal shielding during electron beam therapy using Monte Carlo (MC) simulations and Gafchromic film measurements.
Sukhvir Singh, M. Semwal, Chetna Bhatt
semanticscholar +1 more source
Adaptive radiotherapy may improve treatment outcomes for lung cancer patients. Because of the lack of an effective tool for quality assurance, this therapeutic modality is not yet accepted in clinic.
Hualiang Zhong +5 more
doaj +1 more source
Telah dilakukan penelitian tentang perbandingan dosis serap berkas foton 16 MV pada berbagai jenis material phantom dengan menggunakan simulasi Monte Carlo-EGSnrc.
Ridwan Ramdani, Freddy Haryanto
doaj
EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60 Co HDR brachytherapy source
The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV).The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters.
Anwarul, Islam Mohammad +2 more
openaire +2 more sources
O objetivo deste trabalho é publicar os resultados obtidos de um exercício de intercomparação que envolve a modelagem e simulação de um feixe clínico de um acelerador linear de 6 MV em um campo 10x10 cm², utilizando dois diferentes códigos de Monte Carlo,
Luiz Antônio Castelo e Silva +7 more
doaj +1 more source