Joint Position and General Hypermobility Affect Elbow Joint Congruence on Magnetic Resonance Imaging: A Prospective Cohort Study. [PDF]
Geyer S +7 more
europepmc +1 more source
Tips and Tricks for Hardware Removal and Allograft Fixation After a Failed Latarjet Procedure
Abstract Although relatively rare, recurrent anterior shoulder instability requiring revision surgery after a failed Latarjet procedure can result in complications such as graft malposition, graft osteolysis, broken hardware and/or infection. Revision surgery after a failed Latarjet is a challenge due to a combination of technical factors such as ...
Mikalyn T. DeFoor +7 more
wiley +1 more source
Structural abnormalities of the elbow joint in high school baseball players exposed to the COVID-19 pandemic during their elementary and junior high school years: a sonographic analysis of 354 players at high school entry. [PDF]
Nishi R +6 more
europepmc +1 more source
Lateral Ulnar Collateral Ligament Reconstruction Through a Mini‐Invasive Approach
Abstract Posterolateral rotatory instability is the most common form of elbow instability, secondary to valgus, supination, and axial loading in elbow extension. The lateral ulnar collateral ligament (LUCL) is the primary restraint to posterolateral rotatory instability and multiple techniques of repair and reconstruction of the LUCL have been reported
Valeria Vismara +5 more
wiley +1 more source
Ulnar Compression Neuropathy Secondary to Ganglion Cyst at the Elbow Joint: A Case Report. [PDF]
Basel SK, Shrestha P, Bajracharya GB.
europepmc +1 more source
Abstract The deep layer of the triangular fibrocartilage complex (distal radioulnar ligament) serves as the primary stabilizer of the distal radioulnar joint. Historically, the deep triangular fibrocartilage complex was reattached to the ulnar fovea using bone tunnel or suture anchor techniques to achieve isometric repair.
Yu Jiang +6 more
wiley +1 more source
An Automatic Method for Elbow Joint Recognition, Segmentation and Reconstruction. [PDF]
Cui Y +5 more
europepmc +1 more source
Abstract Arthroscopic‐assisted grafting of the anterior glenoid in instability surgery offers lower morbidity and fewer complications than open techniques but faces challenges in operative field visualization. The 1.9 mm NanoScope (Arthrex, Naples, FL) enables simultaneous arthroscopic views from opposing angles, providing anterior glenoid ...
Joshua C. Y. Ong +4 more
wiley +1 more source
A retrospective comparison of open and arthroscopic surgery for elbow joint stiffness; a single centre pragmatic study over 15 years. [PDF]
Dekker AP, Hind J, Ashwood N.
europepmc +1 more source
Double‐Row Rotator Cuff Repair With Biological Augmentation Using Fibrin Clot‐Loaded Tendon Remnants
Abstract Rotator cuff tears are a common cause of shoulder dysfunction, and the management of remnant tendon during repair remains a clinical challenge. This article describes a technique that preserves tendon remnants by wrapping them in a fibrin clot, thereby enhancing the biological environment at the tendon‐bone interface. The fibrin clot, prepared
Chenyang Meng +4 more
wiley +1 more source

