Results 211 to 220 of about 12,086 (237)
Some of the next articles are maybe not open access.

Electrical Impedance Tomography

Current Opinion in Critical Care, 2009
Electrical impedance tomography (EIT) is a noninvasive, radiation-free monitoring tool that allows real-time imaging of ventilation. The purpose of this article is to discuss the fundamentals of EIT and to review the use of EIT in critical care patients.In addition to its established role in describing the distribution of alveolar ventilation, EIT has ...
Eduardo L V, Costa   +2 more
openaire   +3 more sources

Electrical impedance tomography

IEEE Signal Processing Magazine, 2001
Electrical impedance tomography (EIT) is an imaging modality that estimates the electrical properties at the interior of an object from measurements made on its surface. Typically, currents are injected into the object through electrodes placed on its surface, and the resulting electrode voltages are measured.
Gary J. Saulnier   +4 more
openaire   +1 more source

Electrical impedance tomography

Inverse Problems, 2002
Updated (up to 2002, 153 references) theoretical and numerical studies of the inverse problem for the continuum model of EIT which seeks the admittivity \((\gamma(x)= \sigma(x)+ i\omega\varepsilon(x))\) inside a body \(\Omega\) from the knowledge of the Dirichlet to Neumann (DtN) (or the Neumann to Dirichlet (NtD)) map at the boundary \(\partial\Omega\)
WANG MI, YIN WULIANG
openaire   +5 more sources

Source Consistency Electrical Impedance Tomography

SIAM Journal on Applied Mathematics, 2020
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Tingting Zhang   +5 more
openaire   +2 more sources

Multifrequency electrical impedance tomography

Clinical Physics and Physiological Measurement, 1992
Multifrequency tomography may be conveniently achieved by sequentially sweeping the probing drive current and measuring the resultant voltages at each frequency. If events change during measurement comparisons between frequencies cannot be made. Mixing several frequency components may decrease acquisition time but increase the complexity of the ...
P M, Record, R, Gadd, F, Vinther
openaire   +2 more sources

An electrical impedance tomography microscope

Physiological Measurement, 1996
A circular array of 16 electrodes has been constructed for use as an electrical impedance tomography (EIT) microscope. The electrodes were made from 60 microns diameter gold wires anchored to a printed circuit board. The internal diameter of the array was 0.9 mm giving a theoretical spatial resolution of about 100 microns.
H, Griffiths   +3 more
openaire   +2 more sources

Imaging the complex impedance in electrical impedance tomography

Clinical Physics and Physiological Measurement, 1992
Measuring the reactive component of the bio-impedance enables a full characterisation of the frequency response of a tissue. The amplitude of the reactive component is relatively small in the frequency range generally used in electrical impedance tomography (EIT). Its measurement is therefore more sensitive to errors.
J, Jossinet, C, Trillaud
openaire   +2 more sources

BIOIMPEDANCE TOMOGRAPHY (ELECTRICAL IMPEDANCE TOMOGRAPHY)

Annual Review of Biomedical Engineering, 2006
Electrical impedance tomography (EIT) is a relatively new imaging method that has evolved over the past 20 years. It has the potential to be of great value in clinical diagnosis; however, EIT is a technically difficult problem to solve in terms of developing hardware for data capture and the algorithms to reconstruct the images.
openaire   +2 more sources

A phantom for electrical impedance tomography

Clinical Physics and Physiological Measurement, 1988
A method has been developed for constructing phantoms for electrical impedance tomography (EIT). A mesh of resistors is soldered to pins in a matrix board and forms a physical realisation of a finite element numerical model. To simulate different body tissues, changes in the apparent electrical conductivity and permittivity can be introduced at a ...
openaire   +2 more sources

Electrical impedance tomography/applied potential tomography

Engineering Science and Education Journal, 1993
(a) Established links between active groups within the Electrical Impedance Tomography community in Europe.
openaire   +1 more source

Home - About - Disclaimer - Privacy