Factors Influencing Resistivity Inversion for CO<sub>2</sub> Geological Storage Zones: A Quantitative Study. [PDF]
Wang C +8 more
europepmc +1 more source
A study on the monitoring of LNAPL migration using ERT. [PDF]
Suo K, Zhao M, Liu Y, Liu H, Jia M.
europepmc +1 more source
Integrating geospatial, hydrogeological, and geophysical data to identify groundwater recharge potential zones in the Sulaymaniyah basin, NE of Iraq. [PDF]
Mohammed SH +6 more
europepmc +1 more source
Using roof borehole electrical resistivity tomography to monitor roof water infiltration in a mine work face. [PDF]
Du L +5 more
europepmc +1 more source
The measurement of volume fraction and velocity profiles in vertical and inclined multiphase flows [PDF]
Cory, James
core
Related searches:
Electrical resistance tomography(ERT) by using an ECT sensor
2010 IEEE International Conference on Imaging Systems and Techniques, 2010A sensor typically used in electrical capacitance tomography (ECT) was generalized to reconstruct the conductivity distribution in this paper. Analytical model was established for the sensor. As a result, the sensitivity matrix and the electric field lines can be obtained directly by using the formulae, which are fast and simple.
Zhang Cao +3 more
openaire +1 more source
A new approach to quantify the reliability of Electrical Resistivity Tomography (ERT) images
2023Anthropogenic and natural hazards assessments need a good knowledge of the structures. A classical approach based on geological observations or soil mechanics investigations is often insufficient to characterize both the structures and the nature of subsurface materials.
Gautier, Maxime +2 more
openaire +3 more sources
Interrogation of a precipitation reaction by electrical resistance tomography (ERT)
AIChE Journal, 2005AbstractElectrical resistance tomography (ERT) provides a noninvasive and nonintrusive technique for the full 3‐D interrogation of a typical stirred vessel reactor up to a spatial discrimination of approximately 2,500 derived data points. Some recent ERT results are presented for a newly refurbished 8 ring 16‐sensor 2.3 m3 pilot scale vessel, detecting
S. J. Stanley, R. Mann, K. Primrose
openaire +1 more source
Electrical Resistance Tomography (ERT) applications to Chemical Engineering
Chemical Engineering Research and Design, 2013Abstract Electrical Resistance Tomography (ERT) has the capability of offering time-evolving multidimensional comprehensive process knowledge, enrichment of fundamental process understanding and enhancement of the design and operation of process equipment by measuring the conductivity distribution within a process-plant of interest.
Mohadeseh Sharifi, Brent Young