Results 51 to 60 of about 153,991 (158)
Analysis of Electrical Safety Conditions Taking into Account Soil Conductivity Determined on the Basis of Fuzzy Logic [PDF]
The goal of this work is to prove a possibility of determining soil parameters that influence its conductivity being the basis of grounding, step voltage and touch voltage calculation.
Manusov V.Z., Zaytseva N.M.
doaj
The stable operation of electrical equipment is critical for industrial safety, yet traditional anomaly detection methods often suffer from limitations, such as high resource demands, dependency on expert knowledge, and lack of real-world capabilities ...
Wei Zhou +4 more
doaj +1 more source
Research on 10 kV power supply system for fully-mechanized mining faces
To address the contradiction between the growing power supply capacity demand of fully-mechanized mining equipment and the insufficient power supply capacity of the existing 3.3 kV system, and to promote the safe application of the 10 kV power supply ...
Guangli CHEN, Yong ZHANG, Xiangchun CAO
doaj +1 more source
For power grids with a high penetration level of wind power generation, stochastic wind speed variation adversely affects the frequency stability. A variable-speed wind turbine generator would deloads its output by shifting the power operating point to ...
Min Hwang, Kyung-Soo Kook
doaj +1 more source
A nondestructive safety diagnosis for lithium-ion battery modules was demonstrated with experimental data. The charging curve analysis (CCA) was selected for estimating the internal state of a lithium-ion battery cell and the cell operating conditions in
Kenichiroh Koshika +3 more
doaj +1 more source
Understanding electrical hazards and implementing safety measures is paramount to protecting lives and property. Therefore, this research investigates electrical hazards in households and safety measures taken by residents in Sokode–Etoe, Ghana.
Frank Kulor +4 more
doaj +1 more source
This study investigates the degradation of safety characteristics in commercial NaNi1/3Fe1/3Mn1/3O2 (NFM) sodium‐ion batteries (SIBs) under mild electrical abuse, focusing on the impact of a single electrical abuse event on capacity, impedance ...
Qinghua Gui +5 more
doaj +1 more source
Operating table tipping: A reminder of electrical safety in the operating room.
Subramanian S, Mathew B, Thakur A.
europepmc +1 more source
Improved Radiofrequency Safety Modelling in MRI Using In Vivo Measurements of Brain Conductivity. [PDF]
Paillart G +7 more
europepmc +1 more source

