Results 121 to 130 of about 48,655 (256)
In this work, we developed a highly sensitive and reproducible electrochemiluminescent sensor based on a heterostructure of cadmium selenide quantum dots capped with 3-mercaptopropionic acid (MPA) + 3-morpholinoethanesulfonic acid (MES) (QDs CdSe) and ...
Roodney Alberto Carrillo Palomino +4 more
doaj +1 more source
Advances in cholesterol and lipoproteins detection for healthcare: A review
Cholesterol is one of the main biomarkers related to the development of cardiovascular diseases. Its detection still relies on traditional methods of analysis, such as gas and liquid chromatographies. Detection of free cholesterol in saliva with redox or enzymatic sensors or detection of lipoproteins in blood with aptamer sensors are currently the most
Jacopo Giaretta +7 more
wiley +1 more source
Reactive oxygen species (ROS) have gained increasing attention in electrochemiluminescence (ECL) as endogenous co‐reactants, yet their application in the most widely used tris(bipyridine)‐ruthenium(II) system remains limited due to the scarcity of ...
Zixin Deng +16 more
doaj +1 more source
Glucose (Glu) detection, as a fundamental analytical technique, has applications in medical diagnostics, clinical testing, bioanalysis and environmental monitoring. In this work, a solid-phase electrochemiluminescence (ECL) enzyme sensor was developed by
Chunyin Wei +3 more
doaj +1 more source
Muscle Strength and Power Changes With Gender‐Affirming Hormone Therapy
ABSTRACT Background Androgen receptors are highly expressed in upper body muscles, but changes in maximal muscle strength and power in major upper body muscles have not been investigated during gender‐affirming hormone therapy (GAHT). Objective To assess prospective changes in maximal muscle strength and muscle power from before and after 1 year of ...
Mathilde Kamp Nørlund +12 more
wiley +1 more source
Prognostic value of fetal growth and prenatal functional echocardiography in tetralogy of FALLOT
First demonstration that fetal growth and pulmonary peak velocity at third trimester are independent predictors of postnatal outcome in Tetralogy of Fallot. This may enhance the accuracy of prenatal counseling and facilitate more individualized planning for delivery and neonatal care. Abstract Introduction Tetralogy of Fallot (ToF) shows variability in
Laura Nogué +17 more
wiley +1 more source
Inflammatory Cytokines as Early Predictors of Weaning Failure From Extracorporeal Life Support
Levels of IL‐8 and IL‐6 and their dynamics are reliable early predictors of ECLS weaning failure. ABSTRACT Background Weaning from extracorporeal life support (ECLS) in patients with refractory shock still remains a complex decision. Despite considerable advances in ECLS management, reliable biomarkers to predict weaning success are still not available.
Kostiantyn Kozakov +11 more
wiley +1 more source
Multiphase systems, including ones with liquid‐liquid phase boundaries, are the home to many curious chemistries including reaction acceleration and spontaneous formation of reactive species. Here we show the liquid‐liquid interface causes electrochemiluminescence and afterglow chemiluminescence lifetime to be enhanced by 220,000% in‐time, far beyond ...
Daniel M. Carrel +3 more
wiley +2 more sources
Recent Advances in Aggregation-Induced Electrochemiluminescent Biosensors
Electrochemiluminescence (ECL) biosensors based on aggregation-induced emission (AIE) emitters have recently emerged as highly sensitive tools for biosensing.
Likang Zhou +3 more
doaj +1 more source
The Diagnostic Accuracy of High Resolution Ultrasound Imaging for Detection of Secondary Hyperparathyroidism in Patients with Chronic Renal Failure [PDF]
Ultrasound is one of the preferred modalities for evaluation of the parathyroid glands. This study was undertaken to determine the accuracy of high resolution ultrasound for secondary hyperparathyroidism in patients with chronic renal failure. From March
اناری, حسن +3 more
core

