Results 41 to 50 of about 470,602 (292)
Cephalad extraspinal migration of percutaneously implanted spinal cord stimulator electrodes
Background: Spinal cord stimulation (SCS) is an invasive but beneficial treatment option for patients suffering from chronic pain. Although highly therapeutic, there are some complications that may arise.
Joseph Farshchian +4 more
doaj +1 more source
There is a growing interest in the use of electrocorticographic (ECoG) signals in brain–machine interfaces (BMIs). However, there is still a lack of studies involving the long-term evaluation of the tissue response related to electrode implantation. Here,
Tianfang Yan +6 more
doaj +1 more source
ABSTRACT Objective To determine whether integration of serum neurofilament light chain (NfL) and cortical dysfunction improves diagnostic accuracy in amyotrophic lateral sclerosis (ALS) when applied alongside the Gold Coast criteria (GCC). Methods In this prospective study, 148 participants with suspected ALS were recruited (101 ALS and 47 with ALS ...
Aicee Dawn Calma +16 more
wiley +1 more source
Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating [PDF]
Purpose: To investigate heating during postimplantation localization of intracranial electroencephalograph (EEG) electrodes by MRI. Materials and Methods: A phantom patient with a realistic arrangement of electrodes was used to simulate tissue ...
Lemieux, L. +6 more
core
ABSTRACT Objective Treatment of disorders of consciousness (DoC) remains a major clinical challenge, and noninvasive, targeted modulation of deep brain structures has emerged as a promising therapeutic strategy. We aimed to evaluate the feasibility/safety and preliminary effects of thalamic temporal interference stimulation (TIS) targeting centromedian‐
Gengyao Hu +7 more
wiley +1 more source
Functional MRI with active, fully implanted, deep brain stimulation systems: Safety and experimental confounds [PDF]
We investigated safety issues and potential experimental confounds when performing functional magnetic resonance imaging (fMRI) investigations in human subjects with fully implanted, active, deep brain stimulation (DBS) systems.
Lemieux, L. +15 more
core
IntroductionAlthough deep brain stimulation is nowadays performed worldwide, the biomechanical aspects of electrode implantation received little attention, mainly as physicians focused on the medical aspects, such as the optimal indication of the ...
Frédéric Chapelle +24 more
doaj +1 more source
ABSTRACT Background Stereoelectroencephalography‐guided radiofrequency thermocoagulation (SEEG‐RFTC) is a minimally invasive therapy for drug‐resistant focal epilepsy. However, the relationship between specific seizure‐onset patterns (SOPs), particularly low‐voltage fast activity (LVFA), and postoperative scalp EEG normalization remains inadequately ...
Yi‐qing Yang +6 more
wiley +1 more source
Background Modern prosthetic hands are typically controlled using skin surface electromyographic signals (EMG) from remaining muscles in the residual limb.
Hendrik Adriaan Dewald +6 more
doaj +1 more source
This article investigates the dependence of the properties on the manufacturing orientation in the form of the inclination angle to the build plate of LPBF‐fabricated NiTi rods with a diameter of 150–220 µm. Metallographic, chemical, thermal, and mechanical characterization show behavior under identical manufacturing conditions that ranges from ...
Sandra Herzig +2 more
wiley +1 more source