Results 21 to 30 of about 440,007 (254)
Background and Aim: Deep Brain Stimulation (DBS) surgery is increasingly performed to treat movement disorders. In these patients, a rechargeable or non-rechargeable battery is placed under their subcutaneous chest after implantation of an electrode in ...
Sedigheh Hannani +2 more
doaj
BackgroundInvasive cortical stimulation (ICS) is a neuromodulation method in which electrodes are implanted on the cortex to deliver chronic stimulation.
Ahmad Khatoun +5 more
doaj +1 more source
In patients with drug‐resistant epilepsy who are considering surgery, intracranial EEG (iEEG) helps delineate the putative epileptogenic zone. In a minority of patients, iEEG fails to identify seizure onsets.
Céline Eelbode +6 more
doaj +1 more source
Scaling of Electrode-Electrolyte Interface Model Parameters In Phosphate Buffered Saline [PDF]
We report how the impedance presented by a platinum electrode scales with the concentration of phosphate buffered saline (PBS). We find that the constant phase element of the model scales with approximately the log of concentration, whereas the ...
Jones, Mark Hedley, Scott, Jonathan B.
core +1 more source
Metal ion implanted electrodes for dielectric elastomer actuators [PDF]
This thesis reports on the successful use of low-energy metal ion implantation to fabricate compliant electrodes for miniaturized dielectric elastomer actuators (DEAs, also known as artificial muscles).
Rosset, Samuel
core +2 more sources
Bringing sensation to prosthetic hands—chronic assessment of implanted thin-film electrodes in humans [PDF]
International audienceAbstract Direct stimulation of peripheral nerves with implantable electrodes successfully provided sensory feedback to amputees while using hand prostheses.
Stieglitz, Thomas +64 more
core +2 more sources
Apresentamos o caso de um paciente portador da forma cardíaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de síncope.
Gildo Mota +5 more
doaj +1 more source
Ion-implanted compliant electrodes for mm-size dielectric elastomer actuators [PDF]
The miniaturization of dielectric elastomer actuators requires compliant electrodes that are clean, reliable, and that can be easily patterned on a mm or μm scale.
Dubois, P +7 more
core +1 more source
Relatamos caso de implantação anômala de eletrodo de marca-passo VVI no ventrículo esquerdo (VE), diagnosticada durante avaliação de rotina, dois anos pós-implante. Trata-se de mulher de 65 anos e soropositiva para doença de Chagas.
André Luiz Cerqueira de Almeida +3 more
doaj +1 more source
After the introduction of self-anchoring tined leads in 2002, lead migration after sacral neuromodulation (SNM) in the form of InterStimTM (Medtronic, Minneapolis, MN) has been reduced; however, it remains a considerable complication of this otherwise ...
Leonidas Karapanos +4 more
doaj +1 more source

