Results 111 to 120 of about 501,144 (300)
ALGORITHM FOR CALCULATING THE DISTANCE BETWEEN THE ELECTRODES ON X-RAY IMAGES [PDF]
We propose a method for the segmentation of implanted electrodes and electrodes tips location in X-ray images of the human torso.This work was supported by RF Government Act #211 of March 16 ...
Samiyaa, Yaseen Mohammed +2 more
core
Bilayered PEDOT:PSS–Collagen Scaffolds as Functional Architectures for Tissue Engineering
A bilayered scaffold integrates collagen and PEDOT:PSS as distinct yet interconnected 3D matrices, preserving their fibrillar and conductive characteristics. Spatial compartmentalization enables independent tailoring of each domain while maintaining mechanical stability and compatibility with electrochemical monitoring, providing a multifunctional ...
Rasha Nasser +6 more
wiley +1 more source
Electrochemical characterization of mechanically implanted boron doped diamond electrodes MI-BDD
A new, low production cost, technique for the preparation of boron-doped diamond electrodes (BDD) is presented. The technique is based on mechanical implantation of BDD particles into a titanium substrate.
Comninellis, CH +2 more
core +1 more source
The wear behaviour of ion implanted biomaterials [PDF]
The tribological performance of biomaterials used for artificial joints is of much importance, and require low coefficients of friction, resistance to wear and the ability to withstand many millions of cycles under a multitude of loading regimes ...
Boampong, Derrick Kwadwo
core
Effect of Nitrogen Doping on the Proton‐Irradiation Stability of Carbon Nanowalls
Proton irradiation effects in carbon nanowalls are systematically compared with nitrogen‐doped counterparts over a wide fluence range. While both systems maintain structural integrity, nitrogen incorporation alters the functional response under irradiation.
Baglan A. Kyrykbay +12 more
wiley +1 more source
Intracranial Electroencephalographic Monitoring: From Subdural to Depth Electrodes
At the London Health Sciences Centre Epilepsy Program, stereotactically implanted depth electrodes have largely replaced subdural electrodes in the presurgical investigation of patients with drug-resistant epilepsy over the past 4 years.
Richard S. McLachlan +7 more
core +1 more source
This review outlines critical engineering design rules for building artificial protective coatings on next‐generation lithium metal and silicon battery anodes. It highlights how balancing structural flexibility with strict electronic and ionic transport limits prevents early battery failure.
Surin Gupte, Vilas G. Pol
wiley +1 more source
Locating chronically implanted subdural electrodes using surface reconstruction
ObjectiveTo determine the accuracy of locating subdural electrodes by means of 3-D surface rendering of CT scans. MethodsOpen source software has been developed and posted on the web which segments the electrodes into 3-D surfaces and allows their 3-D ...
Hecox, Kurt E. +6 more
core +1 more source
A VO2 device can act as a functional analog for behavioral timescale synaptic plasticity noted in the mouse brain by current pulsing. ABSTRACT Realizing biologically relevant plasticity rules in hardware is a central goal in neuromorphic computing.
Siddharth Kumar +3 more
wiley +1 more source
An experimental analysis of thick-film solid-state reference electrodes
Thick-Film planar solid-state Silver/Silver Chloride (Ag/AgCl) reference electrodes were developed and tested for ion susceptibility and long term drift in approximately 0.04 M potassium chloride (KCl) solution.
Sophocleous, Marios +3 more
core +1 more source

