Results 121 to 130 of about 99,343 (303)
CORRELATION BETWEEN NEURAL RESPONSE TELEMETRY (NRT) MESUREMENT LEVEL AND BEHAVIORL (T-LEVEL AND C-LEVEL) IN PRELINGUAL COCHLEAR IMPLANT PATIENTS [PDF]
Objectives: To study the correlation between Neural Response Telemetry (NRT) measurement level and behavioral (Threshold level and Comfort level) in pre lingual cochlear implant patients age between 2 -10 years old at one and three months post implant ...
ABDULLAH, ASMA BINTI +2 more
core +1 more source
An Edible H2O2 Biosensor for Gastrointestinal Metabolites and Peroxidase Enzyme Quantification
We present an edible biosensor for gastric fluid analysis that integrates a caffeic acid–horseradish peroxidase redox system into an edible electrolyte‐gated transistor. The device enables rapid, low‐volume detection of H2O2 and, with minimal modification, metabolites and enzyme activity in simulated gastrointestinal conditions.
Valerio Francesco Annese +10 more
wiley +1 more source
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Conductive polymer coatings are widely explored to improve the quality of signals recorded with chronically implanted neural electrodes, offering enhanced biocompatibility along with reduced electrode impedance. Combining computational modelling and data from PEDOT:PTS coated and PtIr electrodes in rats, we show that improvements in signal quality with
Karthik Sridhar +4 more
wiley +1 more source
Implantable optoelectrical devices are an effective resource for the modulation and monitoring of neural activity with high spatiotemporal resolution. This review discusses current challenges faced by these devices and outlines future perspectives for the development of next‐generation neural interfaces targeting chronic, multisite, and multimodal ...
Stella Aslanoglou +4 more
wiley +1 more source
This work pioneers melt electrowriting (MEW) of polyethylene vinyl acetate (PEVA) to fabricate ultra‐compliant, high‐resolution scaffolds. By integrating microscale precision with soft tissue‐like biomechanics, PEVA overcomes stiffness‐driven limitations of conventional MEW polymers, establishing a mechanically biomimetic platform for soft tissue ...
Finn Snow +9 more
wiley +1 more source
This review highlights recent advances in smart face masks that actively monitor breathing. By integrating humidity, gas, temperature, pressure, strain, and triboelectric sensors, these masks track key respiratory parameters in real time. The article summarizes sensor mechanisms, compares performance across studies, and discusses challenges and future ...
Negin Faramarzi +7 more
wiley +1 more source
Deployable medical devices typically need external stimuli to trigger deployment. However, external stimuli are difficult to supply within tissues. Here, we describe a strategy to deploy small‐scale structures into soft tissues after insertion without the need for any stimulus. We demonstrate deployment within a tissue phantom.
Yeh‐Chia Tseng +13 more
wiley +1 more source
Complementary DMOS-VMOS integrated circuit structure [PDF]
A high speed CMOS formed on a single semiconductor substrate includes a DMOS having an asymmetric channel and a VMOS with a relatively short channel length.
Jhabvala, M. O.
core +1 more source
ABSTRACT Magnetogenetic deep brain stimulation (MG‐DBS) represents a wireless neuromodulation that has demonstrated long‐lasting behavioral benefits in Parkinson's disease models. However, the circuit‐level mechanisms underlying these therapeutic effects have remained uncharacterized due to limitations of conventional neural interfaces.
Jakyoung Lee +10 more
wiley +1 more source
Electrographic recording of brain activity through either surface electrodes (electroencephalography, EEG) or implanted electrodes (electrocorticography, ECOG) are valuable research tools in neuroscience across many disciplines, including epilepsy, sleep
Cora Helton +6 more
doaj +1 more source