Results 171 to 180 of about 13,466 (222)
Some of the next articles are maybe not open access.
Vibrating Intrinsic Reverberation Chamber for Electromagnetic Compatibility Measurements
IEEE Latin America Transactions, 2013This paper introduces the basic concepts and implementation of a Vibrating Intrinsic Reverberation Chamber (VIRC). This kind of chambers is used in electromagnetic compatibility testing, and offer some advantages compared to traditional chambers. An introduction, an overview of theoretical principles, a description of the VIRC recently built at the ...
Ramiro Serra, Andres C. Rodriguez
openaire +3 more sources
On the phase statistics of the electromagnetic field in reverberating chambers
IEEE Transactions on Electromagnetic Compatibility, 2001A theoretical model for the electromagnetic field phase statistics within a reverberating chamber is presented. The model is general since it is able to model a completely stirred field and an electromagnetic field in which an unstirred field component is present.
openaire +2 more sources
IEEE Asia-Pacific Conference on Antennas and Propagation
In this paper, the electromagnetic coupling to airborne cables under varied shielding layer (SL) termination methods in a reverberation chamber is investigated.
Minfeng Chen, Zhenyi Niu
semanticscholar +1 more source
In this paper, the electromagnetic coupling to airborne cables under varied shielding layer (SL) termination methods in a reverberation chamber is investigated.
Minfeng Chen, Zhenyi Niu
semanticscholar +1 more source
Investigating electromagnetic exposure of communication cables in reverberant chambers
IEEE International Symposium on Electromagnetic Compatibility, 2003As distributed electronic systems become more complex, the electromagnetic compatibility (EMC) behaviour of the communication cables becomes more significant. Hence a range of test methods must be developed that will provide an adequate measure of the cable's interference susceptibility. One such method is the 'mode stirred reverberation chamber method'
A.J. Willis+3 more
openaire +2 more sources
Research on Electromagnetic Compatibility Validation Scheme for ADAS in Reverberation Chamber
2024 IEEE Joint International Symposium on Electromagnetic Compatibility, Signal & Power Integrity: EMC Japan / Asia-Pacific International Symposium on Electromagnetic Compatibility (EMC Japan/APEMC Okinawa)The high level of integration in the power control unit of electric vehicles facilitates the seamless integration of Advanced Driver Assistance Systems (ADAS) into the vehicle’s electronic architecture.
Xu Zhang+5 more
semanticscholar +1 more source
Acoustic and electromagnetic reverberation chambers: Similarities and differences
2016 Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC), 2016Acoustic reverberation chambers predate electromagnetic (EM) reverberation chambers. EM reverberation chamber researchers occasionally make reference to acoustic equivalents when describing test methods and results. However, most EM reverberation chamber users are not familiar with acoustics and may not be aware of similarities and differences.
openaire +2 more sources
Validation of Vibrating Intrinsic Reverberation Chamber using Computational Electromagnetics
2019 Joint International Symposium on Electromagnetic Compatibility, Sapporo and Asia-Pacific International Symposium on Electromagnetic Compatibility (EMC Sapporo/APEMC), 2019Our study demonstrates a validation of the computational electromagnetics modeling and a simulation of a vibrating intrinsic reverberation chamber (VIRC). The VIRC generates a random electromagnetic environment by shaking the flexible conductive walls to vary the boundary conditions.
Makoto Hara+3 more
openaire +3 more sources
Full Wave Computation of the Electromagnetic Field in Chaotic Reverberation Chambers
2019 International Conference on Electromagnetics in Advanced Applications (ICEAA), 2019The geometry deformation of a rectangular shaped reverberation chamber (RC) improves the field mixing and the chaoticity within the RC, in addition to traditional stirring techniques. We noted how the position and number of hemispherical diffractors affect the RC, evaluating their typical key performance parameter such as the number of uncorrelated ...
Franco Moglie+3 more
openaire +2 more sources
International Conference on Embedded and Multimedia Computing
We have performed pulsed tests on a reference test setup inside two different reverberation chambers. One chamber has a time constant $\tau=1.5 \mu \mathrm{~s}$ while the other has $\tau=0.13 \mu s$.
Alan Aliyali+4 more
semanticscholar +1 more source
We have performed pulsed tests on a reference test setup inside two different reverberation chambers. One chamber has a time constant $\tau=1.5 \mu \mathrm{~s}$ while the other has $\tau=0.13 \mu s$.
Alan Aliyali+4 more
semanticscholar +1 more source
On the use of electromagnetic reverberation chambers for expositure tests of cell tissue
2012 6th Asia-Pacific Conference on Environmental Electromagnetics (CEEM), 2012Investigations of the reaction of biologic tissue to external electromagnetic fields is becoming more and more important in modern day signal environment with its eveqirowing number of electromagnetic emissions, both intended (i.e. cellphones, WLAN-routers, microwave transmission lines) and unintended (i.e.
Kerstin Grutzat+2 more
openaire +2 more sources