Results 31 to 40 of about 1,574 (148)
xx xx. ABSTRACT Fabric‐based wearable electronics are gaining increasing attention owing to their flexibility, breathability, biocompatibility, and seamless integration into clothing. However, most existing studies rely primarily on metallic or carbon‐based conductive materials.
Thirumalaisamy Suryaprabha +6 more
wiley +1 more source
This study presents a liquid metal–engineered β‐PVDF composite enabling high‐performance piezoelectric–triboelectric nanogenerators. Guided by MD/DFT simulations, GaIn doping promotes β‐phase formation and dipole alignment, while native oxides enhance charge retention.
Jiaqi Lu +13 more
wiley +1 more source
ABSTRACT Purpose To demonstrate that a recently reported bright ferritin magnetic resonance imaging (MRI) platform can track transplanted human pluripotent stem cell (hPSC)‐derived cardiomyocytes (hPSC‐CMs) longitudinally and on‐demand in the rat heart.
Keyu Zhuang +12 more
wiley +1 more source
Advanced partial discharge testing of 540V aeronautic motor fed by SiC inverter under altitude conditions [PDF]
The present paper reports non-electrically intrusive partial discharge investigations on an aeronautic motor fed by SiC inverter drive under variable environmental conditions.
Abadie, Cédric +2 more
core +1 more source
This study presents an additive‐free aerosol jet 3D printing technique for assembling 2D MXene nanosheets into complex, customizable, high‐aspect‐ratio 3D microarchitectures without binders. By leveraging real‐time ink thickening, the authors also fabricate 3D microsupercapacitors with interdigitated electrodes that holds breakthrough device areal ...
Chunshan Hu +4 more
wiley +1 more source
A high reliability natural convection airliner actuator permanent magnet motor [PDF]
This paper investigates the opportunity of making a natural convection permanent magnet motor for an airliner high lift actuator. The motor is designed to have a maximum lifespan and reliability: removing liquid or forced air cooling removes a fault ...
Bernot, Alix
core +1 more source
Abstract figure legend Overview of multiscale cardiac remodelling in type 2 diabetes and how to model and simulate these changes using a human‐based, multiscale computational framework. Cardiac remodelling in type 2 diabetes occurs at ionic channel, protein, cellular, tissue and whole‐organ level, affecting the electrophysiological function, mechanical
Ambre Bertrand +2 more
wiley +1 more source
Insights from electromechanical simulations to assess omecamtiv mecarbil efficacy in heart failure
Abstract figure legend Impact of Omecamtiv Mecarbil (OM) on in‐silico models of heart failure. A mathematical electromechanical model of human ventricular tissue is used to simulate the effects of OM in heart failure with reduced ejection fraction (HFrEF).
Maria Teresa Mora +8 more
wiley +1 more source
Repolarization adaptation to rapid change in heart rate in human models – a review
Abstract figure legend This review focuses on non‐invasive assessment of repolarization duration and dispersion (heterogeneity) adaptation to change in heart rate (HR). HR was increased incrementally by left atrial pacing during an electrophysiology (EP) study and by a bolus injection of atropine and in a step up/down fashion by repeated right atrial ...
Lennart Bergfeldt +5 more
wiley +1 more source
Diagnosis of airspeed measurement faults for unmanned aerial vehicles [PDF]
Airspeed sensor faults are common causes for incidents with unmanned aerial vehicles with pitot tube clogging or icing being the most common causes.
Blanke, Mogens, Hansen, Søren
core +4 more sources

