Results 261 to 270 of about 3,126,676 (290)
Some of the next articles are maybe not open access.

Cryo-Electron Microscope Tomography to Study Axonemal Organization

2009
Cilia and flagella are important organelles that perform both motile and sensory functions. For more than half a century, electron microscopy has provided crucial insights into the fundamental architecture and function of these organelles, such as the characteristic [9+2] microtubule arrangement of the axoneme or the dynein-driven microtubule sliding ...
openaire   +2 more sources

Tomography Using the Transmission Electron Microscope

2006
It is evident that electron tomography offers a means to determine the three dimensional structure and composition of many different mateials at the nanometre level. In general, tomography using BF TEM for materials science applications will not yield true reconstructions because of the coherent nature of the scattering process seen in such images.
openaire   +1 more source

Analysis of the Assembly of the HIV Core by Electron Microscope Tomography

1990
Both the proteolytic processing of the p55 gag precursor protein of HIV, myristilation of the p17 (MA) protein, and their morphological rearrangement are necessary to generate structurally mature virus particles (Dahlberg, 1988; Haseltine, 1989). This sequence of events would parallell the observations with e.g.
Stefan Höglund   +6 more
openaire   +1 more source

Tomography experiment of an integrated circuit specimen using 3MeV electrons in the transmission electron microscope

Review of Scientific Instruments, 2007
The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO2 film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view ...
Hai-Bo, Zhang   +3 more
openaire   +2 more sources

Electron Tomography of HEK293T Cells Using Scanning Electron Microscope–Based Scanning Transmission Electron Microscopy

Microscopy and Microanalysis, 2012
AbstractBased on a scanning electron microscope operated at 30 kV with a homemade specimen holder and a multiangle solid-state detector behind the sample, low-kV scanning transmission electron microscopy (STEM) is presented with subsequent electron tomography for three-dimensional (3D) volume structure.
Yun-Wen, You   +7 more
openaire   +2 more sources

Intermediate Voltage Electron Microscopes (IVEM), Electron Tomography, and Single-Particle Electron Microscopy

2003
Contemporary IVEMs as typified by those from JEOL (JEM-2010 and JEM-3010) and FEICO/Philips (Tecnai T20 and Tecnai T30) possess most of the advantages of beam penetration of HVEMs without most of the disadvantages associated with HVEM cost, stability, and Space requirements.
Michael J. Dykstra, Laura E. Reuss
openaire   +1 more source

X-ray micro tomography in the scanning electron microscope

Proceedings, annual meeting, Electron Microscopy Society of America, 1978
Reconstructive tomography is a new technique in diagnostic radiology for imaging cross-sectional planes of the human body /1/. A collimated beam of X-rays is scanned through a thin slice of the body and the transmitted intensity is recorded by a detector giving a linear shadow graph or projection (see fig. 1).
openaire   +1 more source

EMCAT: An automatic image-processing system for electron-microscopic tomography

Proceedings, annual meeting, Electron Microscopy Society of America, 1994
Any real world object is three-dimensional. The principle of tomography, which reconstructs the 3-D structure of an object from its 2-D projections of different view angles has found application in many disciplines. Electron Microscopic (EM) tomography on non-ordered structures (e.g., subcellular structures in biology and non-crystalline structures in ...
Weiping Liu   +2 more
openaire   +1 more source

Automated electron microscope tomography using robust prediction of specimen movements

Journal of Structural Biology, 2005
A new method was developed to acquire images automatically at a series of specimen tilts, as required for tomographic reconstruction. The method uses changes in specimen position at previous tilt angles to predict the position at the current tilt angle. Actual measurement of the position or focus is skipped if the statistical error of the prediction is
openaire   +2 more sources

Grid Computing in Structure Determination of Biological Specimens by Electron Microscope Tomography

2004
The present contribution describes a potential application of Grid Computing in Bioinformatics. High resolution structure determination of biological specimens is critical in BioSciences to understanding the biological function. The problem is computational intensive and distributed computing and Grid Computing are thus becoming essential.
José-Jesús Fernández   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy