Results 21 to 30 of about 3,126,676 (290)
Fully Mechanically Controlled Automated Electron Microscopic Tomography [PDF]
AbstractKnowledge of three-dimensional (3D) structures of each individual particles of asymmetric and flexible proteins is essential in understanding those proteins’ functions; but their structures are difficult to determine. Electron tomography (ET) provides a tool for imaging a single and unique biological object from a series of tilted angles, but ...
Liu, Jinxin +12 more
openaire +4 more sources
Electrostatic charging artefacts in Lorentz electron tomography of MFM tip stray fields [PDF]
Using the technique of differential phase contrast (DPC) Lorentz electron microscopy, the magnetic stray field distribution from magnetic force microscopy (MFM) tips can be calculated in a plane in front of the tip using tomographic reconstruction ...
Scott, J. +3 more
core +1 more source
To investigate how the hydrofluoric acid (HF) concentrations applied to a lithium disilicate glass-ceramic (EMX) affects the surface morphology and microtensile bond strength (μTBS) of ceramics to dentin, using light-cured resin cements with or without ...
Daniel Sundfeld +6 more
doaj +1 more source
The development of field-emission scanning electron microscopes for high-resolution imaging at very low acceleration voltages and equipped with highly sensitive detectors of backscattered electrons (BSE) has enabled transmission electron microscopy (TEM)-
Bogdan Lewczuk, Natalia Szyryńska
doaj +1 more source
Our understanding of the inner structure of metaphase chromosomes remains inconclusive despite intensive studies using multiple imaging techniques. Transmission electron microscopy has been extensively used to visualize chromosome ultrastructure. This review summarizes recent results obtained using two transmission electron microscopy-based techniques:
Phengchat, Rinyaporn +2 more
openaire +2 more sources
Transfer of tilted sample information in transmission electron microscopy [PDF]
When a transmission electron microscope is used in imaging mode, information carried by the sample function is transformed by the optics of the instrument during the imaging process.
Mariani, Valerio
core +1 more source
Biological application of Compressed Sensing Tomography in the Scanning Electron Microscope [PDF]
AbstractThe three-dimensional tomographic reconstruction of a biological sample, namely collagen fibrils in human dermal tissue, was obtained from a set of projection-images acquired in the Scanning Electron Microscope. A tailored strategy for the transmission imaging mode was implemented in the microscope and proved effective in acquiring the ...
Ferroni M +7 more
openaire +3 more sources
Multiscale correlative tomography: an investigation of creep cavitation in 316 stainless steel
Creep cavitation in an ex-service nuclear steam header Type 316 stainless steel sample is investigated through a multiscale tomography workflow spanning eight orders of magnitude, combining X-ray computed tomography (CT), plasma focused ion beam (FIB ...
T. J. A. Slater +8 more
doaj +1 more source
Multi-Beam Scanning Electron Microscopy for High-Throughput Imaging in Connectomics Research
Major progress has been achieved in recent years in three-dimensional microscopy techniques. This applies to the life sciences in general, but specifically the neuroscientific field has been a main driver for developments regarding volume imaging.
Anna Lena Eberle, Dirk Zeidler
doaj +1 more source
DETECTION OF CRACK FORMATION FOLLOWING CORONAL FLARING WITH THREE DIFFERENT INSTRUMENTS USING TWO EVALUATION METHODS (IN VITRO STUDY) [PDF]
INTRODUCTION: Coronal flaring is now considered as an essential preparatory step in root canal treatment sequence. OBJECTIVES: To detect crack formation after coronal flaring of root canals with Gates Glidden (GG) drills, ProTaper Universal (PT) SX, and ...
Nayera A. Mokhless +2 more
doaj +1 more source

