Results 1 to 10 of about 32,735 (279)

Modelling of AlAs/GaAs interfacial structures using high-angle annular dark field (HAADF) image simulations [PDF]

open access: yes, 2012
High angle annular dark field (HAADF) image simulations were performed on a series of AlAs/GaAsinterfacial models using the frozen-phonon multislice method. Three general types of models were considered—perfect, vicinal/sawtooth and diffusion. These were
Craven, A., Finnie, M., Robb, P.D.
core   +1 more source

Thermometry of Silicon Nanoparticles

open access: yes, 2017
Current thermometry techniques lack the spatial resolution required to see the temperature gradients in typical, highly-scaled modern transistors. As a step toward addressing this problem, we have measured the temperature dependence of the volume plasmon
Mecklenburg, Matthew   +2 more
core   +1 more source

Th-U-PbT Dating by Electron Probe Microanalysis, Part I. Monazite: Analytical Procedures and Data Treatment [PDF]

open access: yesGeologia USP. Série Científica, 2010
Dating methodology by the electron probe microanalyser (EPMA) of (Th, U)-bearing minerals, highlighting monazite,acquired greater than ever importance in literature, particularly due to its superior spatial resolution, as well as versatility,which allow ...
Silvio Roberto Farias Vlach
doaj  

Prospects for versatile phase manipulation in the TEM: beyond aberration correction

open access: yes, 2015
In this paper we explore the desirability of a transmission electron microscope in which the phase of the electron wave can be freely controlled. We discuss different existing methods to manipulate the phase of the electron wave and their limitations. We
Béché, Armand   +6 more
core   +1 more source

Estimation of the electron beam-induced specimen heating and the emitted X-rays spatial resolution by Kossel microdiffraction in a scanning electron microscope [PDF]

open access: yes, 2012
Lien vers la version éditeur: http://www.sciencedirect.com/science/article/pii/S0304399112000307A Kossel microdiffraction experimental setup has been developed inside a Scanning Electron Micro-scope for crystallographic orientation, strain and stress ...
BERVEILLER, Sophie   +3 more
core   +4 more sources

High count rate electron probe microanalysis

open access: yesJournal of Research of the National Institute of Standards and Technology, 2002
Reducing the measurement uncertainty of quantitative analyses made using electron probe microanalyzers (EPMA) requires a careful study of the individual uncertainties from each definable step of the measurement. Those steps include measuring the incident electron beam current and voltage, knowing the angle between the electron beam and the sample ...
Geller, Joseph D., Herrington, Charles
openaire   +2 more sources

РЕПАРАТИВНОЕ КОСТЕОБРАЗОВАНИЕ ПРИ ЛЕЧЕНИИ ПЕРЕЛОМОВ КОСТЕЙ МЕЛКИХ ЖИВОТНЫХ ПРИ ПОМОЩИ МИНИФИКСАТОРА ДЛЯ ЧРЕСКОСТНОГО ОСТЕОСИНТЕЗА

open access: yesВетеринарная патология, 2010
The characteristics of reparative osteogenesis have been studied experimentally in linear rats for tibial shaft fracture healing using the mini-fixator for transosseous osteosynthesis worked-out by the authors.

doaj  

electron probe microanalysis

open access: yes, 2014
Citation: 'electron probe microanalysis' in the IUPAC Compendium of Chemical Terminology, 3rd ed.; International Union of Pure and Applied Chemistry; 2006. Online version 3.0.1, 2019. 10.1351/goldbook.E02006 • License: The IUPAC Gold Book is licensed under Creative Commons Attribution-ShareAlike CC BY-SA 4.0 International for individual terms. Requests
openaire   +1 more source

Revealing common artifacts due to ferromagnetic inclusions in highly-oriented pyrolytic graphite

open access: yes, 2012
We report on an extensive investigation to figure out the origin of room-temperature ferromagnetism that is commonly observed by SQUID magnetometry in highly-oriented pyrolytic graphite (HOPG). Electron backscattering and X-ray microanalysis revealed the
A. K. Geim   +8 more
core   +2 more sources

Investigation of the mechanism of mercury removal from a silver dental amalgam alloy [PDF]

open access: yesJournal of the Serbian Chemical Society, 2004
An investigation of silver dental amalgam decomposition and the mercury removal mechanism was performed. The decomposition process was analysed during thermal treatment in the temperature interval from 400 °C to 850 °C and for times from 0.5 to 7.5 h ...
M. DJURDJEVIC, Z. ODANOVIC