Results 51 to 60 of about 1,278 (254)
Evaluation of working length determination methods: An in vivo / ex vivo study
This comparative study was done to determine the accuracy in measuring the working length of root canal using tactile method, electronic apex locator and radiographic method, in viv o, and comparing the lengths so measured to the actual working length,
Shanmugaraj Muthu +3 more
doaj
Gold bipyramids can act as efficient plasmonic nanoheaters, but they often reshape during laser heating. This study shows that oxygen nanobubbles drive oxidative etching and that surface ligands control stability. CTAB‐ and citrate‐coated particles blunt and lose optical performance, whereas polystyrene sulfonate preserves shape and heating by ...
Irene López‐Sicilia +7 more
wiley +1 more source
Kelvin Probe Force Microscopy in Bionanotechnology: Current Advances and Future Perspectives
Kelvin probe force microscopy (KPFM) enables the nanoscale mapping of electrostatic surface potentials. While widely applied in materials science, its use in biological systems remains emerging. This review presents recent advances in KPFM applied to biological samples and provides a critical perspective on current limitations and future directions for
Ehsan Rahimi +4 more
wiley +1 more source
Comparison of the accuracy of NovApex apex locator and radiographic method: in vivo/ex vivo study
INTRODUCTION: Determination of the canal working length with radiographs has many drawbacks. Electronic apex locators have been developed to overcome some of these problems. Recently, a newly designed apex locator called NovApex has been introduced.
Shahriar Shahi +4 more
doaj
Magnetic doping of the topological insulator Bi2Te3 with erbium adatoms induces out‐of‐plane magnetism and breaks time‐reversal symmetry, opening a Dirac gap and driving a Fermi surface transition from hexagonal to star‐of‐David geometry. Microscopy, spectroscopy, and magnetic dichroism reveal atomically controlled magnetic interactions that tailor the
Beatriz Muñiz Cano +18 more
wiley +1 more source
Precision of Working Length Determination of Two Different Apex Locators in Teeth with Periapical Lesion: An In-vivo Study [PDF]
Introduction: Accurate working length determination is critical for the success of root canal treatment. While Electronic Apex Locators (EALs) have improved accuracy compared to radiographs, their performance can be affected by presence of ...
Anithakumari Rangappa +4 more
doaj +1 more source
Resolving the Structural Duality of Graphene Grain Boundaries
Cantilever ncAFM resolves the atomic structure of grain boundaries in graphene, revealing coexisting stable and metastable types. Both contain pentagon/heptagon defects, but metastable GBs show irregular geometries. Modeling shows metastable GBs form under compression, exhibiting vertical corrugation, while stable GBs are flat.
Haojie Guo +11 more
wiley +1 more source
In vitro evaluation of the accuracy of five different electronic apex locators
Objective of Study: To evaluate in vitro the efficacy of five different electronic apex locators (Root ZX II, i-Root, Endo Master, Triauto ZX, and Elements apex locator) in locating the minor diameter.
Nasil Sakkir +5 more
doaj +1 more source
2D α‐Co(OH)2 interleaved with Mo species displays an appealing dual functionality for the production and use of green hydrogen.Mo incorporation greatly benefits the electrochemical behaviour in Oxygen Evolution Reaction for H2 production, while the magnetocaloric response at liquid H2 temperature paves the way for alternative cryogenic refrigerants ...
Daniel Muñoz‐Gil +14 more
wiley +1 more source
The new Cu‐containing MOF (Me2NH2)(CuICl2)@[Cu4(INA)4Cl2O]·1.5dmf (3) contains a cation and an anion as guests and shows UV‐near‐mid‐IR absorption and near‐IR emission. MOF 3 shows gas‐solid reactivity in the presence of NH3 and HCOOH to yield two new 3D MOF.
Rajat Saha +10 more
wiley +1 more source

