Results 101 to 110 of about 7,705 (226)
A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device. [PDF]
In order to guarantee the safe delivery of dynamic intensity modulated radiotherapy (IMRT), verification of the leaf trajectories during the treatment is necessary.
Smitsmans, Monique H P +4 more
core +3 more sources
A Reversible Clearing Strategy Enables Robust Label‐Free Phase Imaging of Thick Tissues
The principle of a reversible clearing strategy via glycerol and tartrazine solution (GTS) for robust whole‐slide label‐free phase imaging of thick tissue slices via high‐throughput Fourier ptychographic microscopy (FPM) and lensless digital holographic microscopy (LDHM). ABSTRACT Thick biological specimens impose strong scattering and attenuation that
Mikołaj Krysa +5 more
wiley +1 more source
ObjectiveA quality control (QC) system based on the electronic portal imaging device (EPID) system was used to realize the Multi-Leaf Collimator (MLC) position verification and dose verification functions on Primus and VenusX accelerators.
Jianfeng SUI +5 more
doaj +1 more source
Dosimetric Performance of A-Si Electronic Portal Imaging Devices
The majority of EPID dosimetry literature discusses response linearity and the so-called image lag and ghosting effects despite the lack of a common definition of these quantities. However, the results of these studies are generally not consistent, and it is often difficult to compare the results from different studies. We present here a detailed study
Alshanqity, M, Nisbet, A
openaire +3 more sources
The Application of Telemedicine in Surgery
This figure provides an overview of the content presented in this article. Telemedicine is integrated throughout the entire surgical workflow, with distinct applications across the preoperative, intraoperative, and postoperative phases. These applications are enabled by a suite of supporting technologies, while the associated implementation challenges ...
Yufan Yang +8 more
wiley +1 more source
Electronic portal imaging device dosimetry in intensity modulated radiation therapy applications. [PDF]
Electronic Portal Imaging Devices (EPIDs) can be used for dosimetric purposes, provided that an appropriate dosimetric calibration is used. However, in most studies published so far, transmitted dose maps, measured using EPIDs, are used under limited ...
Mohammadi, Mohammad
core
This preclinical study evaluated a novel controlled‐expansion expanded polytetrafluoroethylene (ePTFE)‐covered transjugular intrahepatic portosystemic shunt (TIPS) stent in 11 swine, demonstrating 100% technical success, excellent deployability, and durable 6‐month angiographic patency without thrombosis, migration, fracture, or device‐related toxicity.
Yi Xiang +15 more
wiley +1 more source
Evaluation of the mechanical alignment of a linear accelerator with an electronic portal imaging device (EPID) [PDF]
Mechanical misalignment of a medical linear accelerator can be caused by any combination of source position displacement relative to the collimator rotational axis, collimator jaw asymmetry, or when the rotational axes of the gantry and the collimator do
Van Doorn, T., Liu, G., Bezak, E.
core
Biomaterial‐integrated electroporation establishes a programmable therapeutic interface that coordinates electric‐field modulation, transient or irreversible membrane permeabilization, cargo stabilization, and immune remodeling. This Review highlights how nanocarriers, hydrogels, and bioelectronic interfaces expand electroporation from conventional ...
Binbin Ji +13 more
wiley +1 more source
Small field measurements using electronic portal imaging device
Abstract Purpose/Objective. Small-field measurement poses challenges. Although many high-resolution detectors are commercially available, the EPID for small-field dosimetry remains underexplored. This study aimed to evaluate the performance of EPID for small-field measurements and to derive tailored correction factors ...
A Aziz Sait +7 more
openaire +2 more sources