Results 111 to 120 of about 105,168 (294)
Many bench-top flow cytometers (b-FCs) are compatible with microsphere-based multiplexed assays. Disciplines implementing b-FCs-based assays are expanding; they include monitoring and validating food quality. A multiplexed platform protocol was evaluated
Schwartz, Abe +11 more
core +1 more source
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim +6 more
wiley +1 more source
Lunar Calibration for ASTER VNIR and TIR with Observations of the Moon in 2003 and 2017
The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), which is a multiband pushbroom sensor suite onboard Terra, has successfully provided valuable multiband images for approximately 20 years since Terra’s launch in 1999 ...
Toru Kouyama +8 more
doaj +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
EGR-VGT Control and Tuning for Pumping Work Minimization and Emission Control
A control structure is proposed and investigated for coordinatedcontrol of EGR valve and VGT position in heavy duty diesel engines.Main control goals are to fulfill the legislated emission levels, toreduce the fuel consumption, and to fulfill safe ...
Wahlström, Johan, +8 more
core +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source
The nanostructure, size, and function of mRNA‐loaded lipid nanoparticles are evaluated before drying, within polymer microneedles, and after rehydration. The results reveal the polymer and LNP loadings required to recover nanostructure and preserve the delivery performance in dry‐state formulations.
Brendan P. Dyett +19 more
wiley +1 more source
Development of a Real-Time Virtual Nitric Oxide Sensor for Light-Duty Diesel Engines
This study describes the development of a semi-physical, real-time nitric oxide (NO) prediction model that is capable of cycle-by-cycle prediction in a light-duty diesel engine.
Gyujin Kim +3 more
core +1 more source
Operational calibration of a ground-based fully polarimetric radiometer for stratospheric temperature retrievals [PDF]
The oxygen emission band at 60 GHz is a commonly used frequency band for atmospheric temperature sounding. The fine structure emission lines used to retrieve temperature in the stratosphere and mesosphere are affected by the Zeeman effect, which has a ...
W. Krochin +6 more
doaj +1 more source
Orbital Geometry‐Governed Response of Pressure‐Tunable Quantum Defects in hBN
Defects in hBN act as ultrasensitive quantum manometers when the energy of the intradefect optical transitions is modified by lattice compression. The orbital geometry of the electron wave functions governs how electron hopping and Coulomb interactions react uniquely to the reduction of the van der Waals gap and in‐plane compression, leading to robust ...
Magdalena Grzeszczyk +6 more
wiley +1 more source

