Results 21 to 30 of about 14,019 (182)

A Persistently High End-Tidal Carbon Dioxide Value: Can This Be Spurious?

open access: yesJournal of Neuroanaesthesiology and Critical Care, 2019
End-tidal carbon dioxide (EtCO2) monitoring has now become the standard of care not only during anesthesia but also in intensive care units for patients on mechanical ventilation, emergency department, and pre-hospital settings to confirm and monitor the
Barkha Bindu   +3 more
doaj   +1 more source

The association between end-tidal carbon dioxide and arterial partial pressure of carbon dioxide after cardiopulmonary bypass pumping in cyanotic children [PDF]

open access: yesJournal of Cardiovascular and Thoracic Research, 2021
Introduction: Evidence suggests the high capability of non-invasive assessment of the End-tidal carbondioxide (ETCO2) in predicting changes in arterial carbon dioxide pressure (PCO2) following major surgeries in children. We aimed to compare EtCO2 values
Behrang Nooralishahi   +5 more
doaj   +1 more source

END-TIDAL CARBON DIOXIDE MONITORING IN THE NEONATAL VENTILATED PATIENTS USING CAPNOGRAPHY TECHNIQUE

open access: yesPakistan Armed Forces Medical Journal, 2020
Objective: To determine the accuracy and precision of end-tidal carbon dioxide monitoring through capnography in ventilated neonates. Study Design: Quasi-experimental study.
Muhammad Shoaib   +4 more
doaj   +4 more sources

A randomized porcine study of hemorrhagic shock comparing end-tidal carbon dioxide targeted and proximal systolic blood pressure targeted partial resuscitative endovascular balloon occlusion of the aorta in the mitigation of metabolic injury

open access: yesIntensive Care Medicine Experimental, 2023
Background The definition of partial resuscitative endovascular balloon occlusion of the aorta (pREBOA) is not yet determined and clinical markers of the degree of occlusion, metabolic effects and end-organ injury that are clinically monitored in real ...
Anna Stene Hurtsén   +5 more
doaj   +1 more source

Applications of End-Tidal Carbon Dioxide (ETCO2) Monitoring in Emergency Department; a Narrative Review

open access: yesEmergency, 2017
Capnograph is an indispensable tool for monitoring metabolic and respiratory function. In this study, the aim was to review the applications of end-tidal carbon dioxide (ETCO2) monitoring in emergency department, multiple databases were comprehensively ...
Hamed Aminiahidashti   +3 more
doaj   +1 more source

Dynamic optic nerve sheath diameter responses to short-term hyperventilation measured with sonography in patients under general anesthesia [PDF]

open access: yesKorean Journal of Anesthesiology, 2014
BackgroundRapid evaluation and management of intracranial pressure (ICP) can help to early detection of increased ICP and improve postoperative outcomes in neurocritically-ill patients.
Ji-Yeon Kim   +5 more
doaj   +1 more source

Change in the optic nerve sheath diameter after deflation of a pneumatic tourniquet: a prospective observational study

open access: yesScientific Reports, 2022
Applying a pneumatic tourniquet provides surgeons with a bloodless surgical field. However, application of the tourniquet induces various physiological changes.
Ha-Jung Kim   +5 more
doaj   +1 more source

Continuous Measurement of Arterial and End-Tidal Carbon Dioxide during Cardiac Surgery: P a-ET co 2 Gradient [PDF]

open access: yesAnaesthesia and Intensive Care, 1997
There have been reports of a negative arterial to end-tidal CO 2 gradient (P a-ET co 2 ) during cardiac surgery, so we used capnometry and an intravascular blood gas sensor (Paratrend 7) to continuously monitor ...
P S, Myles   +3 more
openaire   +2 more sources

Effect of aminophylline on restoration of spontaneous respiration and recovery profiles during anesthesia without using muscle relaxants in patients undergoing brief gynecological procedure

open access: yesClinical and Experimental Obstetrics & Gynecology, 2020
Purpose of Investigation: The purpose was to evaluate the effects of aminophylline on returning of spontaneous respiration and recovery profiles during propofol-fentanyl-sevoflurane anesthesia without muscle relaxants in patients undergoing day care ...
Y.S. Jeon   +4 more
doaj   +1 more source

Influence of Protective Lung Ventilation on Arterial-To-End Tidal Carbon Dioxide Gradient during One Lung Ventilation: A Prospective Observational Study

open access: yesAirway, 2022
Background: One lung ventilation (OLV) results in a ventilation-perfusion (V/Q) mismatch. Protective lung ventilation (PLV) reduces postoperative pulmonary complications following OLV.
Shruthi C. Pendyala, Aparna Avinash Date
doaj   +1 more source

Home - About - Disclaimer - Privacy