Diagnostic Value of the Anal Endoluminal Functional Luminal Imaging Probe for the Diagnosis of Anismus: An Exploratory Study

open access: yesNeurogastroenterology &Motility, Volume 38, Issue 10, October 2026.
The anal EndoFLIP exhibited a good ability to distinguish patients with anismus from those without based on the composite reference standard (anorectal manometry, surface electromyography, and defecography). ABSTRACT Background and Aims The aim of this exploratory study was to evaluate the performance of the anal EndoFLIP in diagnosing anismus in ...
Charlotte Desprez   +7 more
wiley   +1 more source

Gastroparesis Phenotyping: Current Methods and Emerging Opportunities With Magnetic Resonance Imaging

open access: yesNeurogastroenterology &Motility, Volume 38, Issue 10, October 2026.
Anatomical and dynamic MRI performed before and after ingestion of a natural test meal provide complementary assessments of gastric accommodation, emptying, and regional wall kinematics. This integrated, noninvasive examination supports mechanistic phenotyping of gastric motor dysfunction in gastroparesis. ABSTRACT Background Gastroparesis is a complex
Xiaokai Wang   +2 more
wiley   +1 more source

Comparison of videofluoroscopy and impedance planimetry for the evaluation of oesophageal stenosis: a retrospective study.

open access: yes, 2017
OBJECTIVES To compare videofluoroscopy that included a tablet test with impedance planimetry (EndoFLIP(®)) for the evaluation of oesophageal stenosis in patients with dysphagia.
Ringhofer, Claudia   +5 more
core   +1 more source

Pediatric Esophageal Biomechanics and Remodeling: Integrating Distensibility and Compliance Beyond Luminal Diameter

open access: yesJournal of Gastroenterology and Hepatology, Volume 41, Issue 9, Page 2613-2622, September 2026.
Esophageal distensibility and compliance provide physiologic information beyond luminal diameter alone in pediatric esophageal disease. This review proposes a practical biomechanics‐informed framework integrating FLIP assessment into interpretation of dysphagia, esophageal remodeling, dilation response, and therapeutic decision‐making in children ...
Brett J. Hoskins   +2 more
wiley   +1 more source

Does Measurement of Esophagogastric Junction Distensibility by EndoFLIP Predict Therapyresponsiveness to Endoluminal Fundoplication in Patients With Gastroesophageal Reflux Disease?

open access: yes, 2015
Background/Aims: In patients with gastroesophageal reflux disease (GERD), an increased esophagogastric junction (EGJ) distensibility has been described.
Smeets, F.G.M.   +4 more
core   +1 more source

Divergent Management of the Foregut Between Pulmonologists and Gastroenterologists in Advanced Cystic Fibrosis Lung Disease

open access: yesPediatric Pulmonology, Volume 61, Issue 7, July 2026.
ABSTRACT Background Advanced cystic fibrosis lung disease (ACFLD) remains a major cause of morbidity, particularly in individuals requiring lung transplantation. Gastrointestinal‐related aspiration (GRASP), including reflux and motility disorders, may contribute to adverse respiratory outcomes, yet diagnostic and management strategies vary across ...
Dhiren Patel   +7 more
wiley   +1 more source

Impact of gastric per‐oral endoscopic myotomy on static and dynamic pyloric function in gastroparesis patients [PDF]

open access: yes, 2020
BackgroundFunctional Lumen Imaging Probe (EndoFLIP) tests typically measure static pyloric parameters, but the pylorus exhibits phasic variations on manometry. Dynamic changes in pyloric function have not been quantified using EndoFLIP, and the impact of
Ryan Law   +13 more
core   +1 more source

ç©æ¥­ç®¡çå¬å¸æåå®å¹æ¨¡å¼ä¹å»ºç«

open access: yes, 2014
æåä¹ç©æ¥­ç®¡ç(Property Management, PM)å¬å¸ä¹ç¢åï¼ç©ç®¡æåçå質è广 ¼çºå½±é¿ç©ç®¡å¬å¸ç¶ç績æä¹ééµã檢è¦ç¾ä»ç©æ¥­ç®¡çç¢æ¥­ä¹æ¦æ³ï¼ç±æ¼åå°åå§æ³ä»¤ä¸å¥å¨åé²å¥é檻è¼ä½ä¹å½±é¿ï¼ä»¥è³æ¼ç©æ¥­ç®¡ç業èèæ¼ååç«¶ç­çç°å¢ï¼é²èé ææ¥­èéç«¶ç­åå¹å½±é¿å¶å質è婿½¤ãçºæ­¤ï¼åå ...
è¡æä¿®
core   +1 more source

Accuracy of Novice Raters for Esophageal Motility Classifications Using Functional Lumen Imaging Probe Panometry

open access: yesNeurogastroenterology &Motility, Volume 38, Issue 7, July 2026.
Eight novice raters without motility experience completed brief FLIP panometry training and interpreted 40 studies using v1.0 and v2.0 classification schemes. Accuracy compared to expert consensus was high (v1.0: 0.78, v2.0: 0.73), with good‐to‐moderate interrater agreement (v1.0: κ 0.61, v2.0: κ 0.55).
Cayla E. Bales   +11 more
wiley   +1 more source

EndoFLIP Guided Assessment of Pyloric Distensibility Identifies Associations With Delayed Gastric Emptying and Symptoms of Gastroparesis

open access: yesNeurogastroenterology &Motility, Volume 38, Issue 7, July 2026.
Measuring pyloric distensibility at high balloon volumes using EndoFLIP differentiates normal from delayed gastric emptying, while pyloric stiffness specifically correlates with increased subjective feeling of stomach fullness. EndoFLIP could be a valuable clinical tool to phenotype the pyloric sphincter in symptomatic patients.
Subhankar Chakraborty   +4 more