Results 11 to 20 of about 23,701 (280)

Multi-Center Evaluation of Optical Degradation Patterns in Rigid Endoscopes: A Data-Driven Approach [PDF]

open access: yesMedical Devices: Evidence and Research
Herke Jan Noordmans,1 Menno de Braak,2 Marco J Brakel,1 Alexander R Onur,1 Jeroen De Geus,3 Joris E N Jaspers1 1Department of Medical Technology and Clinical Physics, University Medical Center Utrecht, Utrecht, the Netherlands; 2Research & ...
Noordmans HJ   +5 more
doaj   +2 more sources

Novel technology for automated cleaning of flexible endoscopes [PDF]

open access: yesEndoscopy International Open
Reprocessing of flexible endoscopes is a multi-stage system with many sequential stages. Errors in any one of the stages can result in microbial contamination that persists in patient ready endoscopes despite full reprocessing.
Michelle J. Alfa
doaj   +2 more sources

High Prevalence Rate of Microbial Contamination in Patient-Ready Gastrointestinal Endoscopes in Tehran, Iran: an Alarming Sign for the Occurrence of Severe Outbreaks

open access: yesMicrobiology Spectrum, 2022
An alarmingly increasing number of outbreaks caused by contaminated gastrointestinal (GI) endoscopes are being reported as a particularly concerning issue.
Hamidreza Houri   +19 more
doaj   +1 more source

Study on the effectiveness and compatibility of sterilization of flexible endoscopes using a low temperature steam formaldehyde sterilizer

open access: yesSterile Supply, 2023
ObjectiveTo investigate the sterilization of OLYMPUS flexible endoscopes with a low temperature steam formaldehyde sterilizer of a national brand model FS-130 and to verify its compatibility.MethodsEight flexible endoscopes sterilized in our hospital ...
Aihua Liu
doaj   +1 more source

Efficacy of chlorin dioxide wipes in disinfecting airway devices contaminated with Covid-19

open access: yesFrontiers in Cellular and Infection Microbiology, 2023
BackgroundReprocessing and disinfecting endoscopes is a routine practice in otolaryngology. An effective, safe, and rapid disinfection technique is essential during the COVID-19 pandemicObjectiveTo validate the efficacy of chlorine dioxide wipes in ...
Hussain Albaharna   +5 more
doaj   +1 more source

Endoscope reprocessing: Retrospective analysis of 90,311 samples

open access: yesEndoscopy International Open, 2023
Background and study aims The contamination level of ready-to-use endoscopes published in the literature varies from 0.4 % to 49.0 %. Unfortunately, the comparison and the interpretation of these results are quite impossible, given the limited number of ...
Lionel Pineau
doaj   +1 more source

Thermal Safety of Endoscopic Usage in Robot-Assisted Middle Ear Surgery: An Experimental Study

open access: yesFrontiers in Surgery, 2021
Objectives: The widespread application of endoscopic ear surgery (EES), performed through the external auditory canal, has revealed the limitations of the one-handed technique. The RobOtol® (Collin ORL, Bagneux, France) otological robotic system has been
Jinxi Pan   +19 more
doaj   +1 more source

Optical Analysis of Nasal Endoscopic Images From a Patient With Severe Acute Respiratory Syndrome Coronavirus 2 [PDF]

open access: yesJournal of Rhinology, 2022
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread worldwide; a simple diagnostic test is becoming increasingly important. Polymerase chain reaction tests of nasal swab samples are expensive and time-consuming.
Sujeong Bae, Young Joon Jun
doaj   +1 more source

Automated objective routine examination of optical quality of rigid endoscopes in a clinical setting. [PDF]

open access: yesPLoS ONE, 2013
Rigid endoscopes degrade during clinical use due to sterilization, ionizing radiation and mechanical forces. Despite visual checks on functionality at the department of sterilization, surgeons are still confronted with suboptimal instruments as it is ...
Rens Wientjes   +3 more
doaj   +1 more source

Establishment of a quality control circle to reduce biofilm formation in flexible endoscopes by improvement of qualified cleaning rate

open access: yesJournal of International Medical Research, 2020
Objective In recent years, the Emergency Care Research Institute has advised that endoscope cleaning is of considerable importance. In the present study, a quality control circle (QCC) was used to reduce the formation of biofilms in flexible endoscopes ...
Yingxia Luo   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy